Omron E2B-M18KS05-M1-B2 active, but check supply

E2B-M18KS05-M1-B2 Omron product image

10V to 30V, 5mm shielded M18 inductive sensor, PNP-NC 3-wire, -25°C to 70°C, IP67

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 5MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 600Hz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

Still a valid design-in, but not with this stock position

And yes, the lifecycle call is straightforward: E2B-M18KS05-M1-B2 is still a valid new design-in because every lifecycle field says Active and there is no listed conflict. That settles obsolescence. It does not settle sourcing.

The release blocker is simpler. Stock is 1, which may cover a prototype but does not support a running line. The listing also carries a compliance conflict: one field says RoHS Compliant, another says RoHS Non-Compliant, so EU RoHS remains unresolved until that is cleared.

5mm is the fit limit that matters first

5mm comes first. If the target and mounting stackup need more than 0.197" (5mm), this part is out before wiring or enclosure details matter.

Can your machine use a PNP-NC M18 inductive sensor?

Can the control side actually use a PNP-NC, 3-wire sensor? That is the first real buyer question, because this part is not electrically interchangeable with every inductive prox sensor that shares the same body size.

The output is PNP-NC, 3-wire, so the PLC input card and field wiring need to expect that logic state and wiring style. If they do not, the mismatch shows up immediately at integration rather than later in qualification.

Mechanical fit is just as specific. The sensor is shielded, built in a Cylinder, Threaded - M18 body, uses connector termination, has nickel-plated brass construction, and carries an IP67 rating. That points to machine frames, brackets, and washdown-adjacent industrial mounting where an M18 threaded barrel is already the intended hole pattern, but it still leaves the deciding details open: connector orientation, mating interface, and body length are not listed, and those are exactly the details that determine whether nearby hardware clears the sensor or blocks the cable exit.

The operating temperature range is -25°C to 70°C. Useful, but not complete. It defines the ambient range the part is meant to handle, while leaving self-heating, panel hot spots, and installations where local metal temperature rises above ambient unresolved.

The 600Hz response frequency helps frame the application too. It separates this part from slow presence sensing only, but it is still a ceiling for event rate, not proof that every target geometry at every gap will switch cleanly at that speed.

600Hz helps, but the datasheet gaps are the real hold-up

600Hz is not the hold-up. The missing items are: pinout, mechanical drawing, connector detail, and switching diagram.

Without those, the exact wiring assignment, the body dimensions around the M18 thread, and the connector exit remain open.

View the Win-Source product page for E2B-M18KS05-M1-B2.

Key Takeaways for Engineers & Buyers

  • Match the input card to PNP-NC, 3-wire before releasing E2B-M18KS05-M1-B2.
  • Hold production planning until stock moves past 1 piece.
  • Clear the RoHS conflict before any compliance-sensitive build.