10V ~ 30V supply, 5mm shielded M18 inductive body, 600Hz response, -25°C ~ 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 600Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Wrong for long-range sensing, right for tight metal targets
Not for stand-off detection. The listed sensing distance is 0.197" (5mm), so this sensor fits jobs where the target is brought deliberately close to the face, not ones with bracket drift, runout, or a loose mechanical stack that needs extra reach.
What it does offer is a defined fit: inductive sensing, shielded construction, and a Cylinder, Threaded - M18 body. That points to flush-mounted metal detection in machinery, fixtures, and guarded positions where you want the barrel to disappear into metalwork without the sensing field wandering. The NPN-NC, 3-Wire output narrows the audience fast; if your control input expects a different logic convention, E2B-M18KS05-WP-C2 2M is the wrong sensor before mounting is even discussed.
The weak point is availability; the electrical window is usable
Stock is the weak point. The listed quantity is 1, so this is not a part to drop into a running line today unless you already have coverage elsewhere or you are buying a single spare to keep equipment moving.
The electrical and environmental window is otherwise usable for mainstream industrial control. A 10V ~ 30V supply range works across common control cabinets, but it does not answer noise immunity, surge behavior, or edge-of-range performance under cable drop. The -25°C ~ 70°C operating temperature is a ceiling and floor for ambient use, not a promise that every enclosure condition inside that band stays safe once self-heating and nearby hot hardware enter the picture.
IP67 helps, but only to a point. It closes the door on ordinary dust and temporary water ingress concerns, while leaving chemical washdown compatibility, connector sealing practice, and cable abuse unanswered.
Speed matters too. A 600Hz response frequency is enough for many position and presence jobs, yet it remains a ceiling that decides whether a fast tooth wheel, cam edge, or short target dwell can be seen cleanly, especially when machine timing leaves little margin for missed transitions. Get that wrong and the symptom is missed counts, not graceful degradation.
View the Win-Source product page for E2B-M18KS05-WP-C2 2M.
One conflict needs clearing before release
The constraint is documentation. The compliance block says RoHS Compliant, while a specification line says RoHS Non-Compliant.
Lifecycle is Active, which supports new design-in once that contradiction is settled.
5mm is only half the story
5mm tells you the reach, not the install risk. The listing does not carry the pinout or wire color function for the 3-wire cable, and that is the first missing item because NPN-NC only gets you partway to a correct PLC landing.
The other gaps are the mechanical drawing, target requirements, and switching hysteresis. With a threaded M18 shielded body, the drawing decides panel thickness, nut stack, and face position. The target spec decides whether that 0.197" (5mm) number holds for your metal and geometry or collapses in the real machine. Hysteresis decides chatter at the trip point.
View the Win-Source product page for E2B-M18KS05-WP-C2 2M.
Key Takeaways for Engineers & Buyers
- Match the input card to NPN-NC, 3-wire before releasing E2B-M18KS05-WP-C2 2M.
- Hold the rail inside 10V ~ 30V across startup and brownout, not just at nominal supply.
- Resolve the RoHS conflict and the stock count of 1 before putting E2B-M18KS05-WP-C2 2M on a running line.