Omron E2B-M18KS08-WP-C1 2M active, but buy carefully

E2B-M18KS08-WP-C1 2M Omron product image

10V to 30V supply, 8mm shielded inductive range, M18 threaded body, -25°C to 70°C, IP67

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 8MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

10V to 30V decides the control cabinet, not the machine

10V to 30V is the first gate. It puts E2B-M18KS08-WP-C1 2M on a standard industrial DC rail, not in a lower-voltage sensor node, and the listing says nothing about output load, inrush, or line immunity.

The other number that drives the mechanical call is 0.315" (8mm). For a shielded inductive sensor, that is the sensing ceiling you design around; if the target sits farther out, this part is the wrong pick. Keep the 500Hz response frequency in view as well. It fits ordinary machine-state detection, but it is not a motion-control timing spec.

The real fit is fixed mounting with ordinary industrial timing

So the package matters just as much as the electrical line. A Cylinder, Threaded - M18 format with a nickel-plated brass body puts this sensor into bracketed machine mounting rather than tiny fixtures or dense embedded assemblies, while Cable Leads means the design has to accommodate a flying lead instead of a connectorized sensor swap.

IP67 and -25°C to 70°C settle part of the environmental question, not all of it. IP67 supports use around dust and washdown spray better than an open sensor would, but it does not answer chemical compatibility for the nickel-plated brass body or the cable jacket because that detail is not listed. The -25°C to 70°C operating range supports ordinary indoor and light outdoor industrial service, yet it still leaves high-heat enclosure placement, freezer shock, and hot-soak recovery unanswered.

Output Type is NPN-NO, 3-Wire. That narrows integration fast: use it where the input card expects an NPN normally open sensor, and stop if the PLC standard is PNP or the machine harness was built around another output convention. The LED indicator is useful during commissioning. It does not change the architecture.

Thin stock is the only reason to hesitate

Thin stock is the weak point, while lifecycle is not. E2B-M18KS08-WP-C1 2M is marked Active, and EU RoHS is clear, but the quantity picture is split between 1 and 88.

Treat that as a buy-side constraint. For a running line, lock the exact quantity before release. For a new program, don't assume availability is broad just because status is healthy.

What the listing still doesn't answer

Wrong for final interface and mounting release. Right for early selection, where the rail, body style, sensing distance, and output convention are already clear.

The missing items are concrete: pinout or lead identification for the 3-wire cable, a mechanical drawing for thread length and body dimensions, and load or output-current detail for the NPN-NO stage.

View the Win-Source product page for E2B-M18KS08-WP-C1 2M.

Key Takeaways for Engineers & Buyers

  • Hold the rail inside 10V to 30V; this sensor does not close a lower-voltage input design.
  • Reserve E2B-M18KS08-WP-C1 2M for targets that sit inside the 8mm sensing ceiling of a shielded M18 body.
  • Resolve the stock split now: one field shows 1 and another shows 88 for E2B-M18KS08-WP-C1 2M.