10V ~ 30V, 10mm inductive range, M18 threaded body, -25°C ~ 70°C, IP67, 400Hz response
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Stock is the weak point; the sensor itself is usable
The weak point is obvious: stock is 1. That alone makes this a poor choice for a fresh production release unless supply is lined up first.
The stronger signal is lifecycle. Status reads Active without a conflict, so this does not look like an end-of-line part. That supports use in new design-in when the one-piece stock position is acceptable, and it makes even more sense for sustaining builds where a single unit can unblock a machine or cover a short run.
One issue still blocks a clean release. RoHS is conflicted here, with both Compliant and Non-Compliant shown, so EU RoHS status stays unresolved until that record is cleared.
Wrong for flush mounting, right for dirty industrial sensing
Flush mounting in metal is the wrong starting point. The listing calls this sensor unshielded, so nearby metal can change how much the 0.394" (10mm) sensing distance means in practice.
In a more typical machine setup, it fits the job well enough: M18 threaded cylinder, nickel-plated brass body, cable leads, and IP67. The 10V ~ 30V supply range sets a hard operating window, while the PNP-NC, 3-wire output quickly narrows the wiring scheme. Output current, voltage drop, and PLC input compatibility are still not stated, and those details decide whether the electrical side is easy or annoying.
400Hz is enough, but only for modest event rates
400Hz is the ceiling. Fast indexing or fine tooth counting may outrun it, while simple presence detection usually won't.
The missing electrical details are the real review gap
And that is the real gap. The listing covers sensing format and the 10V ~ 30V supply window, but it leaves out output load current, residual voltage, current consumption, and any timing detail beyond 400Hz. For a PNP-NC sensor, those are the values that determine whether a PLC input sees a clean state and whether cable length or input burden starts to matter.
The mechanical picture is incomplete in the places that stop a release. There is no drawing, no pinout beyond cable leads, and no cable detail despite the 2M identifier in the part number. E2B-M18LN10-WP-B2 2M may still be the right sensor, but final fit and wiring checks depend on the manufacturer datasheet because those concrete details are missing here.
View the Win-Source product page for E2B-M18LN10-WP-B2 2M.
Key Takeaways for Engineers & Buyers
- Hold E2B-M18LN10-WP-B2 2M for builds that can live inside 10V ~ 30V only.
- Reserve the single listed unit now if this sensor is needed for an existing machine stopgap.
- Clear the RoHS conflict on E2B-M18LN10-WP-B2 2M before BOM release.