16mm sensing, M18 threaded body, 10V to 30V supply, -25°C to 70°C, IP67, NPN-NO 3-wire output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 16MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you release it into a new build now?
Can this go into a new build now? On lifecycle, yes. On timing, not cleanly.
Active status shows no conflict, so this is a valid new design-in candidate rather than a sustaining-only part. EU RoHS is also straightforward here.
Availability is the problem. Listed quantity is 1, which makes E2B-M18LN16-WP-C1 2M a poor just-in-time dependency for a production order. Use it where a sourcing pause is acceptable, or lock supply before the BOM goes live.
16mm is the real placement decision
16mm sets the first mechanical call. The listed sensing distance is 0.630" (16mm), so this belongs either on short-standoff metal detection or on a fixture that needs more air gap. Because the sensor is unshielded, that number alone does not settle flush-mount behavior; the keep-out still has to come from the datasheet.
The electrical fit is narrow and useful
The constraint is interface fit. This is an inductive industrial proximity sensor with an NPN-NO, 3-wire output, so it belongs where the receiving input expects a sinking sensor, not in a slot meant for PNP outputs or contact closures.
The 10V to 30V supply range decides rail compatibility across common industrial control voltages. It does not answer output current, voltage drop, or leakage, so PLC input loading and pull-up choices remain open. The 400Hz response frequency matters too, but it is a ceiling on event rate, not a promise that every installation will switch cleanly at that speed once target size, spacing, and mounting metal enter the picture.
The rest of the build points the same way. A threaded M18 cylindrical body, nickel-plated brass housing, cable leads, and IP67 ingress rating place E2B-M18LN16-WP-C1 2M in fixed industrial mounting for wet or dirty equipment, not compact embedded electronics or connectorized quick-swap sensor blocks.
What the listing still doesn’t tell you
Not enough yet.
The missing details are the ones that decide whether E2B-M18LN16-WP-C1 2M drops into a real machine without rework. Unshielded is listed, but the flush or non-flush mounting rules are not. Cable leads are listed, but cable length beyond the part suffix is not spelled out in the specifications block, and neither conductor assignment nor pinout appears here. The supply range is present, but output current, residual voltage, and off-state leakage are absent, so the input-side electrical fit is still unresolved.
And the mechanical gaps are just as concrete. There is no drawing with body length, thread length, nut hardware, or sensing-face dimensions, even though those dimensions decide bracket depth, jam-nut clearance, and whether the target can actually enter the sensing field the way the machine layout assumes.
View the Win-Source product page for E2B-M18LN16-WP-C1 2M.
Key Takeaways for Engineers & Buyers
- Match the input stage to NPN-NO, 3-wire switching before assigning E2B-M18LN16-WP-C1 2M to an existing harness.
- Check the mechanical stack around the 0.630" (16mm) sensing distance and unshielded M18 body before freezing bracket spacing.
- Reserve stock now if this build needs E2B-M18LN16-WP-C1 2M soon; listed quantity is 1.