10V ~ 30V supply, 15mm shielded range, M30 threaded body, -25°C ~ 70°C limits
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 15MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Stock, not lifecycle, is the first constraint
Availability is the constraint the numbers create. Lifecycle is not the problem: E2B-M30LS15-M1-B2 is listed as Active, so the question for a new design is less about status than about whether you can support a build when the visible quantity is 1.
The rest of the listing is specific enough to make substitution awkward once a machine is laid out. You have a 10V ~ 30V supply, 0.591" (15mm) sensing distance, PNP-NC, 3-Wire output, shielded construction, and a Cylinder, Threaded - M30 body. That points to machine sensing work where the bracket, harness, and PLC input style are usually settled early, and where a later sensor change can force mechanical and wiring rework at the same time. EU RoHS is straightforward. If E2B-M30LS15-M1-B2 fits the architecture, it belongs in the design; if the build needs near-term coverage, secure quantity before BOM release.
Wrong for fast targets; right for slow machine presence sensing
Fast detection is not its job. At 250Hz, E2B-M30LS15-M1-B2 is a poor fit where the target passes quickly or the timing window is narrow, and the listing gives no faster switching figure to soften that limit.
It fits slower industrial presence sensing on a standard DC sensor rail. The 10V ~ 30V range works with common control voltages, but it is only the supply window, not proof of output compatibility with every input card. The bigger integration call is the PNP-NC, 3-Wire output. That belongs in control schemes built around sourcing outputs and normally closed logic. The 0.591" (15mm) sensing distance gives useful stand-off, and the shielded construction helps when the mounting hardware is tight and side field spread needs to stay controlled.
15mm and M30 decide the mechanical fit
15mm sets the sensing envelope. Here, that gives you more stand-off than a near-contact arrangement, but the listing stops at nominal distance and says nothing about how detection shifts with target material.
The package matters just as much. Cylinder, Threaded - M30 with a nickel-plated brass body is a large-format industrial mounting choice, not something you tuck into a cramped fixture wall. IP67 and -25°C ~ 70°C support use in dirty equipment areas and ordinary plant temperature swings, yet both are ceilings, not operating targets: IP67 says nothing about every chemical exposure, and -25°C ~ 70°C is the environmental limit without any derating detail. The LED indicator helps during setup. It won't fix a bad mounting position.
The missing details are the ones that close the review
Some details are still missing.
E2B-M30LS15-M1-B2 still needs the connector pinout, the mechanical drawing, and the output current detail to finish I/O and harness decisions.
The sensing curve versus target condition and any mounting guidance tied to the shielded body matter too, because 15mm alone does not tell you how much margin is left once the real target and bracket geometry are in play.
View the Win-Source product page for E2B-M30LS15-M1-B2.
Key Takeaways for Engineers & Buyers
- Match the input rail to 10V ~ 30V before assigning E2B-M30LS15-M1-B2 to a panel design.
- Use E2B-M30LS15-M1-B2 where 15mm sensing distance and a shielded M30 body fit the mechanics.
- Cover the line requirement now; listed stock is 1 for E2B-M30LS15-M1-B2.