10V to 30V supply, 4 mm sensing, PNP-NC 3-wire output, M8 threaded body, -25°C to 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 4MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
The real constraint is output logic, not lifecycle
The constraint is logic compatibility. Active status and EU RoHS compliance are straightforward; the real gate is whether the control side expects a normally closed PNP, 3-wire inductive sensor in an M8 cable-lead body.
Can you actually buy into a running line now?
Can you get enough parts to support a line now? Only if you treat supply as the immediate limit.
Lifecycle is clean at Active, but listed stock is 1, so E2B-S08KN04-WP-B2 2M works for qualification or a controlled release and is weak for an unattended production ramp.
Bulk packaging and cable leads point to a field-mount sensor, not a pick-and-place item. Lock the source before you freeze the BOM.
4 mm sensing decides the mechanical fit before 30 V does
0.157" (4mm) is the number that sets the fit first.
It places E2B-S08KN04-WP-B2 2M in short-range metal target detection, where bracket position and target repeatability are already controlled, and it still leaves open the practical questions around offset, side approach, and nearby metal because the listing calls the sensor unshielded, which changes how tightly hardware can sit around the sensing face.
The 10V ~ 30V supply is a compatibility window, not a performance guarantee. It supports use on common industrial rails, but it does not state output current, voltage drop, or what the receiving input sees at the edge of that range. Get that interface wrong and the field symptom is familiar: the sensor switches, the LED says so, and the controller misses the event.
Response frequency at 1kHz matters too. It separates this device from slow presence sensing, but it still leaves pulse-width limits, target-size dependence, and cable-length effects unanswered. E2B-S08KN04-WP-B2 2M fits compact machine sensing, conveyor position checks, and guarded metal detection points where IP67 and a stainless steel body matter more than long reach.
What the listing still doesn't tell you
Not enough yet.
The missing details are concrete: pinout or lead-color assignment for the 3-wire cable, a mechanical drawing beyond "Cylinder, Threaded - M8," and load or output-current detail for the PNP-NC stage. Mounting guidance tied to the unshielded construction is also absent, and that's where nuisance trips usually start.
View the Win-Source product page for E2B-S08KN04-WP-B2 2M.
Key Takeaways for Engineers & Buyers
- Match the input card to PNP-NC, 3-wire behavior before releasing E2B-S08KN04-WP-B2 2M.
- Check the machine geometry against the 0.157" (4mm) sensing distance and unshielded mounting.
- Reserve stock early; current quantity is 1 for E2B-S08KN04-WP-B2 2M.