1mm inductive range, 10V to 30V supply, M8 threaded body, -25°C to 70°C, PNP-NO 3-wire output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 1MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you put this into a new build?
Can this go into a new build? Yes, if the machine already wants a PNP-NO, 3-wire inductive sensor in a threaded M8 body with a cabled connection.
Lifecycle is not the problem. Fit is. The 1mm sensing distance is a hard mechanical limit, and it rules the part out anywhere target position, vibration, or bracket tolerance can drift. RoHS is also unresolved here: one field says compliant and another says non-compliant. Clear that before the BOM is frozen.
1mm is the number that decides the whole design
1mm decides it.
The listed sensing distance is 0.039" (1mm). That is a very short ceiling, not a forgiving operating point, so the design burden shifts straight to mechanics: target repeatability, bracket stiffness, and mounting control all have to stay tight if this sensor is going to behave consistently in service.
Electrical fit is only partly answered by the listing. The supply range is 10V ~ 30V, which puts it on common industrial control rails within that window, but that alone does not close the I/O question. Output current, voltage drop, and load behavior are not given, so input-card compatibility is still only partially defined even though the output style is PNP-NO, 3-wire.
Speed looks usable, with a listed response frequency of 2kHz. That gives the part a credible place in fast presence detection on small moving hardware, but it is still just the ceiling stated in the listing. There is no switching waveform here, and there is no output load detail either, so the number should not be stretched into timing data the page does not provide.
Environmental limits are practical, not broad. Operating temperature is -25°C ~ 70°C and ingress protection is IP67. Those limits support dirty equipment and wet areas better than open assemblies do, yet they still leave real questions open for the application, including chemical exposure, cable flex life, and thermal drift.
The weak point is stock; the strong point is packaging fit
Stock is the weak point first: only 1 piece is listed.
The stronger case is physical fit. Stainless steel body, shielded construction, threaded M8 cylinder, cable leads, and an LED indicator make sense in cramped metal tooling and small brackets where a larger barrel sensor will not fit. It is less attractive where fast connectorized replacement or extra sensing margin matters, because the 2M cabled format and 1mm range work against both.
What the listing still does not tell you
10V ~ 30V isn't enough.
The missing details are the pinout for the 3-wire cable, the mechanical drawing for the M8 threaded body, the output current detail, and the target/material dependence behind the 1mm sensing distance.
View the Win-Source product page for E2B-S08LS01-WP-B1 2M.
Key Takeaways for Engineers & Buyers
- Match the PLC input card to PNP-NO, 3-wire before locking E2B-S08LS01-WP-B1 2M.
- Hold the target stack-up to the 1mm sensing distance; this part gives little mechanical slack.
- Resolve the RoHS conflict before release, and don't count on stock beyond the listed 1 piece.