90V ~ 264V supply, 55 mA draw, transistor output, -10°C ~ 55°C operating range
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensors, Transducers Amplifiers |
| Package | Bulk |
| Core function | AMP 90-264VAC FOR E2C PROX |
| Key electrical range | Current - Supply: 55 mA; Operating Temperature: -10°C ~ 55°C; Output Type: Transistor; Voltage - Supply: 90V ~ 264V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you put E2C-AK4A into a new build now?
Can you release it into a new build now? Yes, if the design already calls for an AC-powered amplifier in an E2C proximity arrangement.
E2C-AK4A is marked Active with no lifecycle conflict, so status alone does not block a new design. The real issue is supply. Listed stock is 1 and package is Bulk, which is too thin to support a production release until availability is locked down. RoHS compliance clears one routine compliance check, but it does not change the immediate quantity constraint.
The AC rail decides this part more than the output does
This is the main filter.
The listed 90V ~ 264V supply range settles the first decision quickly: E2C-AK4A fits where mains-derived AC is already present, and it is out of bounds for low-voltage DC sensor rails. That one number narrows the field before sensing performance even enters the discussion, because a part built around that input range is only useful in installations that can actually provide it.
Next comes the 55 mA supply current. It matters because it sets the upstream power budget for the amplifier channel rather than the sensor head by itself, so it is enough for high-level feed sizing. It does not answer startup behavior, surge, or internal dissipation, and those gaps keep it from closing protection or thermal decisions on their own.
The transistor output gives you the broad interface type and tells you the switching is electronic rather than relay-based, but that still leaves the practical integration questions open. Without output current, voltage limits, or polarity detail, you cannot close the PLC input match or the load-side decision with confidence.
Temperature is the other hard boundary. The -10°C ~ 55°C operating range is the allowed operating window, not a suggested target, so colder outdoor cabinets and hotter enclosed panels are out unless the actual ambient stays inside that band. In a controlled factory enclosure, E2C-AK4A can fit cleanly. In harsher corners of a plant, it may not.
Not for low-voltage sensor rails
Not for low-voltage sensor rails. It fits installations that already have 90V ~ 264V available and need an amplifier in the E2C proximity chain. The category and description point to a dedicated sensor amplifier role, not a general-purpose interface block.
1 unit is the real blocker
1 unit is the blocker.
That number shifts the conversation from design fit to build timing. Active status keeps E2C-AK4A in play, but stock of 1 limits it to evaluation, service, or a tightly controlled pilot build until supply is confirmed.
A few concrete gaps still matter: no pinout, no mechanical drawing, no output electrical limit, and no mounting detail beyond Bulk packaging. Those missing details decide cabinet wiring, mating hardware, and whether the transistor output actually matches the receiving input.
View the Win-Source product page for E2C-AK4A.
Key Takeaways for Engineers & Buyers
- Match the power source to 90V ~ 264V AC before assigning E2C-AK4A to the BOM.
- Hold release for volume builds until stock moves past 1.
- Check the mating E2C proximity head and output interface; this listing only says transistor output.