20 mm inductive head, 50 Hz response, cable leads, -25°C to 70°C, and it requires an external amplifier
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: Requires Amplifier; Response Frequency: 50Hz |
| Reported stock | 1 pcs reported — confirm on RFQ |
The real constraint is the missing electronics
The constraint is architectural, not dimensional. “Requires Amplifier” is the line that decides the fit, because this is an inductive sensing head rather than a complete prox switch, and that pushes it into designs already built around a separate amplifier, along with the extra wiring, mounting, and fault handling that split arrangement brings. If the job calls for a self-contained threaded sensor with direct output, this listing does not finish the job.
The rest of the specs tighten the window. The 0.787" (20mm) sensing distance gives useful mechanical reach, but the unshielded construction means nearby metal and mounting geometry still shape real performance; the 20 mm figure is not a free pass to bury the head in steel and expect the same result. The 50Hz response is a ceiling, not a normal operating point, and it cuts off fast event detection well before body style becomes the main issue. In practice, E2C-C20MA fits slower industrial position sensing where an external amplifier is already part of the control scheme, not compact retrofits that need all electronics in the barrel.
Active status helps, but stock does not
New design-in is reasonable.
Active status appears clean, with no stated conflict, and EU RoHS is compliant. That supports E2C-C20MA for fresh designs and existing production. The supply picture is the harder limit: listed stock is 1, with bulk packaging. Secure supply before releasing E2C-C20MA into a running build.
20 mm is useful, but only in the right mechanics
20 mm is the key figure. It gives E2C-C20MA room in larger fixtures and machine frames, but the unshielded threaded body points it toward open mounting conditions rather than crowded metalwork where side metal can distort the sensing field.
50Hz sets the speed limit, and the datasheet gaps are real
50Hz is the listed response-frequency ceiling. That number determines whether E2C-C20MA can track the event rate in your machine, but it does not cover switching delay, pulse fidelity, or behavior near the edge of the sensing zone. Those are the details that turn into missed counts or unstable detection in the field.
Some concrete items are still missing here: supply voltage, output electrical details at the amplifier interface, pinout or lead assignment for the cable, and a mechanical drawing beyond “Cylinder, Threaded.” There is also no indicator, so setup and fault finding will depend on the external amplifier rather than the sensor head.
View the Win-Source product page for E2C-C20MA.
Key Takeaways for Engineers & Buyers
- Match E2C-C20MA only to an amplifier-based sensing chain; the head does not stand alone.
- Check machine speed against the 50 Hz response ceiling before freezing detection timing.
- Lock supply early if E2C-C20MA is approved; listed stock is 1 and package is bulk.