12V ~ 24V supply, 45 mA draw, NPN twin output, -10°C ~ 55°C: usable limits, but not for new builds
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensors, Transducers Amplifiers |
| Package | Bulk |
| Core function | SMART PROX SENSOR |
| Key electrical range | Current - Supply: 45 mA; Operating Temperature: -10°C ~ 55°C; Output Type: NPN; Voltage - Supply: 12V ~ 24V |
| Reported stock | 1 pcs reported — confirm on RFQ |
New design-in is off the table
Don't design this in.
Discontinued status already settles the question, and the separate EOL lifecycle flag only reinforces it. For a new program, the answer is no. For existing production, treat it as sustaining-only: secure what you need for field support and start the migration now, because stock is listed at 1, and that single unit cannot cover production demand, service exposure, and normal attrition at once.
The electrical details are still useful for triage. The 12V ~ 24V supply range shows which control rails can host it, 45 mA supply current tells you what it adds to the cabinet power budget, and the NPN twin output points to the downstream input style. Those facts help you assess installed use, but they do not offset the lifecycle risk. EU RoHS compliance matters for regulated builds, yet it does not change the sourcing decision.
Can you actually buy enough to keep a line moving?
Can I get enough parts to keep production going?
No. This listing shows stock at 1, package as Bulk, and the part as discontinued.
That matters more than any electrical field here. One loose unit may cover troubleshooting, a repair bench, or a final service event. It does not support a production release, and it will not absorb fallout if E2C-EDA21 2M appears on multiple assemblies. Reserve it for an existing machine already in the field, then remove E2C-EDA21 2M from any open new-build demand.
The rail and temperature limits decide the fit
The constraint is operating envelope.
A 12V ~ 24V supply range confines use to control systems already built around those rails. It says nothing about transient tolerance, brownout behavior, or startup sequencing, so those decisions remain open until fuller documentation is in hand. The -10°C ~ 55°C operating temperature range is also a hard ceiling and floor. It can fit indoor machinery or mild industrial enclosures, but it does not close outdoor, hot-panel, or cold-start use where ambient margin disappears first.
The 45 mA supply current is modest, but it is still a fixed load on the sensor supply. Twin Output and NPN make the interface direction clear enough for a sinking-input ecosystem, but they do not establish output current, response behavior, or wiring detail.
The missing datasheet items are the real blocker
The weak point is documentation depth.
The few listed numbers are usable, but the omissions stop the job. There is no pinout, no mechanical drawing, and no mounting detail, so you cannot close cable routing, panel cutout, or replacement fit from this page. There is also no output current rating, no switching or response-time figure, and no load detail for the NPN twin outputs. Those gaps, more than anything else, block a clean sustaining release even before the discontinued status enters the discussion.
View the Win-Source product page for E2C-EDA21 2M.
Key Takeaways for Engineers & Buyers
- Lock the rail at 12V ~ 24V; E2C-EDA21 2M does not close any decision outside that supply window.
- Budget 45 mA supply current per amplifier in the control cabinet load plan.
- Quarantine the single listed unit for service stock, not a fresh BOM release.