10V ~ 30V supply, 70 mA draw, panel mount, -10°C ~ 55°C: sustaining use where E2CA-X2A/-5M is locked in
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensors, Transducers Amplifiers |
| Package | Bulk |
| Core function | AMP DC 4-20MA FOR E2CA-X2A/-5M |
| Key electrical range | Current - Supply: 70 mA; Operating Temperature: -10°C ~ 55°C; Output Type: Linear; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Discontinued first, application-specific second
The weak point comes first: E2CA-AL4D is discontinued, and the lifecycle fields also use EOL language, so it does not belong in a new build. The useful part is narrower. The description ties it to E2CA-X2A/-5M and a DC 4-20 mA output path, which is enough to support an existing machine when that sensor chain is already fixed.
The verdict is simple. Keep it for sustaining designs or field service on installed equipment. EU RoHS compliance stays relevant for regulated assemblies, but it does not change the lifecycle stop.
Not for general sensor front ends
This is the wrong pick for a general-purpose amplifier just because it offers linear output.
It fits panel-mount builds already using E2CA-X2A/-5M, where the 10V ~ 30V supply range matches the cabinet rail and the 70 mA supply current is already budgeted.
The listed limits narrow the cabinet, not the circuit
And that narrow fit comes straight from the few numbers that are actually here. The 10V ~ 30V supply range sets rail compatibility for E2CA-AL4D, but it does not answer loop compliance, transient tolerance, or behavior at the ends of that range under load, which is exactly where a panel build can look fine on paper and still turn into a commissioning problem.
The 70 mA current - supply figure is only a consumption number to budget in the control panel. It is not a signal-drive number, and it is not a time-domain spec. That closes one decision cleanly: whether the upstream supply can spare that current for the amplifier. It does not close output loading, cable length, or fault behavior on the 4-20 mA side, because those details are not listed.
Temperature is the other hard limiter. The listed -10°C ~ 55°C operating range is a ceiling and floor for E2CA-AL4D, and it can rule the unit out quickly in outdoor cabinets, washdown areas, or hot enclosures where ambient rises before the rest of the system is stressed. Panel mount helps with placement, but panel mount is packaging, not thermal permission.
Buy only to cover an installed base
Buy sparingly.
With quantity listed at 1 and bulk packaging, E2CA-AL4D is a last-piece service buy, not something to count on for a running line.
If you still need it, reserve that unit against a named machine or spare kit now, then treat every open demand as a migration problem because the lifecycle status already says the line has ended.
What the listing still doesn't answer
What do you still need to know first? Pinout and wiring detail. Without them, cabinet integration does not close from this page alone. Output load or loop compliance for the 4-20 mA path is also missing, and that is the detail that decides what receiver and cable run it can actually support.
There is no mechanical drawing, and there is no fuller environmental detail beyond -10°C ~ 55°C. For a panel-mounted amplifier, those are the gaps that stop a clean release.
View the Win-Source product page for E2CA-AL4D.
Key Takeaways for Engineers & Buyers
- Block E2CA-AL4D from new BOMs; lifecycle is Discontinued and stock shows 1.
- Check the host rail against the 10V ~ 30V supply window before changing the panel cutout.
- Confirm the 4-20 mA loop requirements with the E2CA-X2A/-5M chain; this listing gives no load or wiring detail.