Omron E2CA-AL4E discontinued, sustaining use only

E2CA-AL4E Omron product image

10V ~ 30V supply, 70 mA draw, panel mount, -10°C ~ 55°C: enough to place it, not enough to reopen a platform choice

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategorySensors, Transducers Amplifiers
PackageBulk
Core functionAMP DC 4-20MA FOR E2CA-X5A/-5M
Key electrical rangeCurrent - Supply: 70 mA; Operating Temperature: -10°C ~ 55°C; Output Type: Linear; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

The real constraint is lifecycle, not the rail

The limiting factor is lifecycle. E2CA-AL4E is marked Discontinued in lifecycle status and product status, with an EOL signal alongside them, so it does not belong in a new release even if the electrical listing looks easy to accommodate.

It still fits sustaining use where the build already depends on an amplifier for E2CA-X5A/-5M. RoHS compliance avoids a separate materials issue, but availability decides the outcome here. Treat E2CA-AL4E as a keep-running part only.

Can you actually buy enough to keep a line moving?

Can you buy enough to support production? No.

The listed stock is 1, and that single unit matters more than any electrical number because it turns E2CA-AL4E into a service-risk item rather than something you can schedule against for ongoing builds.

The rest of the commercial picture points the same way. Package is Bulk, so there is no reel or tray convention to simplify incoming handling, and the lifecycle conflict between EOL and Discontinued still resolves in one practical direction: assume no replenishment you can count on. Put the remaining piece against field support or line-down exposure, and move any open demand tied to E2CA-AL4E into an engineering change path now.

This is the longest pole in the tent. A part can have a workable 10V ~ 30V supply window and still be the wrong choice when available quantity is 1 and every lifecycle field says the line has ended.

10V to 30V and 70 mA set the integration envelope

10V ~ 30V is the supply ceiling range. It answers one question: whether the control cabinet rail can host this amplifier at all.

The 70 mA current-supply figure is also a listed ceiling for rail budgeting around E2CA-AL4E, not a statement about dynamic output behavior. Pair that with the linear 4-20 mA description and panel-mount format, and the fit becomes specific: cabinet or machine-panel sensing chains already built around E2CA-X5A/-5M. The -10°C ~ 55°C operating temperature range narrows it further. It belongs in controlled industrial ambient, not hotter enclosures or cold outdoor installs unless the full assembly has already been proven there.

The missing details are exactly the ones that close review

Too much is missing.

E2CA-AL4E is identified as an amplifier for E2CA-X5A/-5M, but this listing does not include pinout, panel cutout or drawing, or output accuracy details for the 4-20 mA path.

It also omits response-time behavior and any load-driving limit on the linear output. Those details decide wiring, loop compatibility, and whether it can drop into an existing panel without surprises.

View the Win-Source product page for E2CA-AL4E.

Key Takeaways for Engineers & Buyers

  • Lock E2CA-AL4E to existing E2CA-X5A/-5M assemblies only.
  • Check the rail against the 10V ~ 30V supply limit before touching the panel design.
  • Reserve the single listed unit for service or line-down exposure, not prototype work.