Omron E2CA-AN4E discontinued, sustaining use only

E2CA-AN4E Omron product image

10V ~ 30V supply, 70 mA draw, panel mount, -10°C ~ 55°C: enough to fit a cabinet, not enough to reopen a platform

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategorySensors, Transducers Amplifiers
PackageBulk
Core functionAMP AC 4-20MA FOR E2CA-X5A/-5M
Key electrical rangeCurrent - Supply: 70 mA; Operating Temperature: -10°C ~ 55°C; Output Type: Linear; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

Discontinued status closes the new-design question

The constraint is lifecycle. E2CA-AN4E is marked Discontinued, with an EOL signal alongside it, so it is out for new design-in even though it is EU RoHS compliant.

One unit on hand changes the buying move

Buy only for sustainment.

With stock at 1, the move is straightforward: treat E2CA-AN4E as a line-down spare for equipment already built around the E2CA-X5A/-5M pairing named in the description, not as material for qualification or a fresh release. Bulk packaging barely matters here. Availability is the limit.

Wrong for platform work, right for a specific installed base

Wrong for platform work first. Any program that needs a stable forward supply plan should rule this out, and any installation outside -10°C ~ 55°C should do the same because that range is the listed operating ceiling and floor, not a target.

It still fits a narrow installed-base job. In a panel-mounted cabinet already using the E2CA-X5A/-5M arrangement called out in the product description, E2CA-AN4E can match the existing setup if the rail stays within 10V ~ 30V. That supply range answers a basic compatibility question, but it says nothing about noise tolerance, startup behavior, or what happens near either end of the range under load, which is exactly where retrofit work tends to get messy.

The 70 mA supply current matters too. It sets what the control power budget must carry for the amplifier itself, but it does not describe output drive capability or loop behavior. The listed output is Linear and the description says 4-20MA, so the fit is plainly instrumentation-oriented rather than a simple switching sensor interface, yet the page still stops short of the details needed to reopen a design around E2CA-AN4E with confidence.

70 mA is listed, but the hard review gaps are elsewhere

70 mA is the stated supply current, and it helps with cabinet power budgeting, but it does not finish the electrical review for E2CA-AN4E.

The real gaps are concrete: pinout, mechanical drawing, and output-side detail for the stated 4-20MA function are not shown here. The listing also does not show connection method or any transfer characteristics for the linear output, so you can't judge integration effort or interchangeability inside an existing assembly from this page alone.

View the Win-Source product page for E2CA-AN4E.

Key Takeaways for Engineers & Buyers

  • Lock any E2CA-AN4E demand to existing E2CA-X5A/-5M builds only.
  • Check the cabinet rail against the 10V ~ 30V supply window before touching the BOM.
  • Reserve the single listed unit for failure recovery, not pilot builds.