0.4mm to 2mm range, 10kHz response, M12 threaded body, -25°C to 70°C, amplifier required
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX IND 0. |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: Requires Amplifier; Response Frequency: 10kHz |
| Reported stock | 0 pcs reported — confirm on RFQ |
Wrong for new builds, still usable on a running line
Wrong for new machines. E2CA-X2A is discontinued, stock is 0, and the lifecycle conflict runs only between EOL and Discontinued.
It still fits existing production already built around this exact inductive head and its matching amplifier chain. EU RoHS is compliant, but that does not change design-in status.
The amplifier dependency is the catch, not the sensing head
The weak point comes first. Output Type is Requires Amplifier, so E2CA-X2A does not complete a sensor channel on its own, and the electrical interface, switching behavior, and system fit still depend on the external amplifier.
What it does offer is a tight sensing envelope. The listed 0.016" ~ 0.079" (0.4mm ~ 2mm) distance puts it in very short-range position detection, not general presence sensing across a loose mechanical stack-up. Miss that window and the failure mode is straightforward: missed detection at the edge of travel. The 10kHz response frequency points to fast events, but output loading and amplifier-side timing are still not stated here.
Can you actually buy E2CA-X2A now?
No. Quantity is 0, and package is Bulk, so there is no reel or tray detail here to ease the supply problem.
Treat E2CA-X2A as sustaining-only for existing production. Freeze demand, count the installed base, and reserve any found stock for service or line-down exposure instead of letting it flow into general purchasing.
It fits tight, wet, fast sensing points
Narrowly, yes.
E2CA-X2A fits applications where a shielded inductive sensor in a Cylinder, Threaded - M12 body has to sit close to metal, tolerate IP67 exposure, and react quickly enough that 10kHz matters more than reach. The -25°C ~ 70°C operating temperature is an ambient range ceiling and floor, not a full thermal picture of the assembly.
The M12 threaded cylinder, nickel-plated brass body, and cable leads mark it as a machine-mounted sensing head for fixed installation. No Indicator matters in maintenance-heavy equipment: if a station stops seeing parts, the sensor gives no local visual state, so troubleshooting shifts to the amplifier or controller. That's acceptable in enclosed tooling and much less convenient on open production equipment where technicians expect a quick visual check.
The missing details are exactly the ones that finish the decision
0.4mm to 2mm is the decisive figure.
It tells you where E2CA-X2A operates mechanically, but not enough to close a control decision. The listing places the sensor head in a very short sensing window and identifies the package style, yet the amplifier-side electrical behavior that determines integration is still absent, and that missing layer is what stops a clean replacement or reuse decision.
The first gap is supply voltage, shown only as -. For a sensor that requires an amplifier, that blocks interface planning immediately. The second is pinout or lead assignment; Cable Leads is not a wiring diagram, and without conductor functions you cannot land it in a harness or check compatibility with an installed amplifier. The third is a mechanical drawing beyond Cylinder, Threaded - M12, because thread callout alone does not settle body length, sensing face geometry, or mounting clearance.
The fourth gap is switching detail. There is no switching distance curve, no hysteresis figure, and no output timing detail beyond 10kHz, so edge stability near the 0.4mm and 2mm limits is still unresolved.
View the Win-Source product page for E2CA-X2A.
Key Takeaways for Engineers & Buyers
- Block E2CA-X2A from new BOMs; lifecycle is Discontinued and stock is 0.
- Check the mating amplifier first; E2CA-X2A will not function standalone.
- Keep target position inside the 0.4mm to 2mm sensing window on any existing line.