12V ~ 24V supply, 45 mA draw, NPN open collector, -10°C ~ 55°C ambient ceiling
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensors, Transducers Amplifiers |
| Package | Box |
| Core function | AMPLIFIER NONFERROUS PROX |
| Key electrical range | Current - Supply: 45 mA; Operating Temperature: -10°C ~ 55°C; Output Type: NPN - Open Collector; Voltage - Supply: 12V ~ 24V |
| Reported stock | 1 pcs reported — confirm on RFQ |
45 mA is small, but it still sets the rail budget
45 mA sets the first hard limit. On E2CY-SD11 2M, that is the stated supply draw, so it is the number that immediately claims space on the sensor power rail before you decide anything else.
The rest of the electrical envelope is specific enough to narrow fit quickly: 12V ~ 24V supply and an NPN - Open Collector output. That makes E2CY-SD11 2M a match for control systems already built around that voltage span and sinking-style sensor interfaces, while leaving pull-up choice, output current limit, and wiring details unresolved because those figures are not listed here.
Wrong for wide-temperature builds, right for ordinary control panels
Wide-temperature builds are the wrong target. If ambient falls below -10°C or rises above 55°C, E2CY-SD11 2M is outside its stated operating range and the enclosure has to keep the amplifier within that band.
Inside that window, the fit is straightforward. This is an amplifier for a nonferrous proximity setup, not a general-purpose sensor block, and the category and description place it in machine sensing chains that already expect a separate amplifier stage. The NPN open-collector output keeps it aligned with PLC and controller inputs wired for that output style. The package field says Box, but that still leaves board footprint and mounting unanswered.
Buy it for new work only if quantity is already covered
Active is clear.
Availability is the constraint. Stock is listed at 1, so E2CY-SD11 2M is not something to treat as freely available for a running line or a fresh build unless quantity is already secured elsewhere. For new work, use it only when supply is covered. For existing production, that single unit is better held for bring-up or failure analysis than consumed where continuity matters. EU RoHS is in place, so compliance doesn't complicate the decision.
What the listing still does not answer
And that still leaves the concrete gaps: pinout or wiring diagram, output current capability for the open collector, and mounting or dimensional information. Without them, interface loading, cable termination, and panel fit stay open.
View the Win-Source product page for E2CY-SD11 2M.
Key Takeaways for Engineers & Buyers
- Budget 45 mA from the 12V ~ 24V rail for each E2CY-SD11 2M channel.
- Match the controller input to an NPN open-collector output before releasing the schematic.
- Reserve the on-hand piece now if you need E2CY-SD11 2M for debug; listed stock is 1.