10V to 30V supply, 2mm sensing, 3.5kHz response, IP67 cylinder, -25°C to 70°C limits
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 3.5kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
The real constraint is reach, not lifecycle
The constraint is distance. New design-in is reasonable, but only for very short-range metal detection.
Lifecycle does not block it. E2E-C03N02-WC-B1 2M is Active, the lifecycle signals agree, and EU RoHS is compliant. The hard fit question is the 0.079" (2mm) sensing distance. If the target and mounting stack need more air gap than 2mm, this sensor is out before wiring or controls enter the discussion. The unshielded construction matters too, pushing the review toward surrounding metal and mounting geometry rather than just the PLC input type.
3.5kHz is fast enough only if the mechanics fit first
3.5kHz is the decisive figure for response. It keeps this from being just a slow presence switch and gives room for fast part detection and short event spacing, but it does not rescue a bad mechanical stackup because the 0.079" (2mm) sensing distance still sets the first pass-fail line.
The supply range does the same kind of gatekeeping. With a 10V ~ 30V ceiling, the sensor fits common industrial DC rails inside that window and simply does not belong outside it, so this is an integration limit, not a performance talking point.
Temperature closes part of the application question as well. The listed -25°C ~ 70°C operating range covers ordinary factory ambient, washdown-adjacent enclosures, and outdoor cabinets in mild climates, but it does not settle high-heat mounting near motors or tooling, where local temperature can outrun cabinet air by a wide margin. Watch the mount.
The PNP-NO, 3-Wire output narrows the fit in a useful way. It suits control schemes expecting a sourcing output and cable-lead field wiring, and it does not suit input cards, harness standards, or fault models built around a different output behavior.
This belongs on compact metal targets, not forgiving fixtures
2mm is a tight envelope. That puts it on fixtures where the target is controlled, repeatable, and close, not on stations that rely on generous stand-off to survive vibration, bracket drift, or sloppy changeover.
The cylinder body, stainless steel construction, cable leads, and IP67 rating point to machine-mounted industrial use where physical abuse and fluid exposure are normal. The LED indicator helps during setup and fault finding. What remains open is the exact mounting geometry, because the listing gives no drawing or pinout detail beyond cable leads, and that missing mechanical detail decides how the unshielded body behaves in the bracket.
Can you actually buy it for a build?
Can you get enough of it? Not freely. Stock is listed at 1, so E2E-C03N02-WC-B1 2M is a poor choice for an immediate running line unless you already have coverage elsewhere.
View the Win-Source product page for E2E-C03N02-WC-B1 2M.
Key Takeaways for Engineers & Buyers
- Hold the rail inside 10V to 30V; that range decides whether E2E-C03N02-WC-B1 2M is even in play.
- Treat 2mm as the sensing ceiling and account for the unshielded body before freezing bracket geometry.
- Secure stock early; listed quantity is 1 even though lifecycle is Active.