10V to 30V supply, 2mm sensing, 3.5kHz response, IP67 cylinder sensor with one compliance conflict
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 3.5kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Still a valid design-in, but not a blind one
And the main call is still straightforward: this is a live part you can design in, because every lifecycle signal says Active and there is no lifecycle conflict to explain away.
The problem is compliance, not age. One field says RoHS Compliant while another says RoHS Non-Compliant, so it is not cleared for a release that needs EU RoHS until that contradiction is resolved against the exact ordering code. Keep the lifecycle verdict and the compliance verdict separate. They are different issues.
2mm is the limit that decides the mechanics
2mm sets the boundary. The listed sensing distance is 0.079" (2mm), so this sensor belongs in close-in metal detection where target position is controlled, not in wider stand-off sensing.
The 10V ~ 30V supply range answers a different question: rail compatibility. It covers common industrial DC rails, but it does not tell you output current, voltage drop, or load behavior, so it does not clear the PLC input or interface stage by itself. Then there is 3.5kHz response frequency, which points to fast presence detection rather than only slow limit-style feedback, though the listing still leaves out timing detail that would settle pulse-width tolerance or edge behavior in the machine.
Would it fit this machine and can you buy it now?
Can I put this on the line now? That is usually the first real question.
On physical fit, this sensor is easy to place in industrial equipment that wants an inductive sensor in a cylinder body with cable leads, an LED indicator, stainless steel housing, and IP67 sealing. Unshielded is the detail that changes the installation. It brings different mounting and nearby-metal constraints than a shielded barrel sensor, so it suits layouts where the mechanical envelope can respect that field, not crowded brackets where surrounding metal is already tight.
The host side is just as specific. NPN-NC, 3-Wire is not a generic interface, and if the control input expects a different logic convention, this is the wrong sensor even when the barrel, ingress rating, and operating temperature range of -25°C ~ 70°C look right on paper. That temperature figure is an ambient operating window, not a promise about every enclosure condition once local heating and cable routing are added.
Availability is the immediate constraint. Stock is 1. That supports a bench check or a repair stopgap, not a confident production position, and if this exact Omron sensor is already frozen into a build, reserve the unit you need now rather than assuming near-term depth from a single listed piece.
The weak point is the missing detail, not the sensor body
The weak point is the missing detail. The sensor body is not the issue.
The listing is usable, but it stops short of the details that close an electrical and mechanical release. What is missing is the pin or wire assignment, a dimensional drawing for the cylinder body, and output-side electrical limits such as load current. The response frequency is listed, but the connection detail, mounting drawing, and fuller timing detail are not, and those are what decide whether it drops into an existing harness and bracket without rework.
View the Win-Source product page for E2E-C03N02-WC-C2 5M.
Key Takeaways for Engineers & Buyers
- Hold release on E2E-C03N02-WC-C2 5M until the RoHS conflict is cleared.
- Check the control input against NPN-NC, 3-Wire before freezing the I/O map.
- Reserve stock now if you need E2E-C03N02-WC-C2 5M immediately; listed quantity is 1.