0.8mm sensing, 10V to 30V supply, NPN-NC 3-wire output, IP67 cylinder, -25°C to 70°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCT 0. |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 5kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Not for generous sensing margin
This is the wrong sensor when the machine can only offer a loose target position or a dirty mechanical stack-up. The listed sensing distance is 0.032" (0.8mm), and that number decides the fit: very short-range metal detection, not a station expected to absorb alignment drift.
It does fit compact industrial presence sensing where a shielded inductive cylinder is the intended geometry and the control side expects NPN-NC, 3-Wire. The 10V ~ 30V supply range gives rail flexibility, but it does not settle interface polarity or wiring conventions by itself. Active lifecycle supports new design-in, while the RoHS call remains unsettled because one field says compliant and another says non-compliant.
The weak point is reach; the strong point is speed
The short reach comes first. A 0.032" (0.8mm) sensing distance is a hard application limit, not a tuning target, so it only works when the metal target can be brought very close and kept there across tolerance, vibration, and wear.
The stronger number is the 5kHz response frequency. That gives it a place in faster detection tasks where a slow prox would miss transitions, but only after the mechanics already respect the 0.8mm ceiling. Then the environmental envelope helps: IP67, stainless steel body, and -25°C ~ 70°C operating temperature point to dirty or washdown-prone industrial mounting, yet those are still limits, and they do not answer cable flex life, impact tolerance, or thermal behavior at the ends of the range.
And the package choice is already made
And that choice is straightforward. Cable Leads and a Cylinder body mean field wiring and a mechanical-first installation. Bulk packaging changes nothing electrically, but it does tell you this is not arriving in a pick-and-place flow.
Can you actually put it on a running line?
Can you get enough of it? Stock quantity is 1, so the first issue is not lifecycle but whether pilot, service, or production can be covered without a stop. Keep it to qualification samples or a very small sustaining need until supply is lined up.
A second release blocker sits right behind availability. One field says RoHS Compliant, another says RoHS Non-Compliant. Clear that before it lands on any controlled BOM, because that mismatch can stall approval after the electrical fit is already done.
The missing details are the ones that close the review
The constraint here is simple: the listed numbers narrow the use case, but they do not finish the selection. It is identified as an inductive, shielded, cylindrical sensor with LED indication, yet the listing does not carry the pinout or wire color assignment, and that matters immediately in any NPN-NC, 3-Wire retrofit where a wrong lead map becomes a startup fault.
The mechanical picture is still incomplete. There is no drawing beyond Cylinder, no body dimensions, and no mounting detail, so thread size, barrel length, and the keep-out needed to decide whether the shielded construction fits the bracket are still unknown.
Electrical gaps remain. There is no load current figure, no voltage drop or residual voltage on the output, and no leakage figure, all of which decide PLC input compatibility and whether the sensor will switch cleanly in an existing control circuit rather than sit in the gray zone between on and off.
View the Win-Source product page for E2E-C03SR8-WC-C2 5M.
Key Takeaways for Engineers & Buyers
- Lock the target around the 0.8mm sensing distance; this is not the part to rescue loose mechanical tolerance.
- Match the input stage to NPN-NC, 3-wire behavior before committing to an existing sensor harness.
- Resolve the RoHS conflict and secure stock early; listed quantity is 1.