10V to 30V supply, 2mm shielded inductive range, 3kHz response, IP67 cylinder, -25°C to 70°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
The 2mm range is the design constraint
The constraint is reach. With a listed sensing distance of 0.079" (2mm), the mechanics get decided before the 10V to 30V supply range settles the wiring, and any target wander, vibration, or tolerance stack that pushes beyond that window rules this sensor out fast.
From there, the rest of the fit is straightforward. Shielded construction and a cylindrical stainless steel body suit close-packed industrial hardware where nearby metal is unavoidable, while IP67 and -25°C to 70°C place it in ordinary washdown and factory ambient rather than extreme heat or outdoor cold. The 3kHz response matters for counting and position work, but it is still a ceiling on switching speed, not evidence that machine timing closes around E2E-C06S02-WC-B2 5M, especially since the listing gives no overtravel behavior, no target-size condition, and no switching hysteresis.
So the part fits new design-in only when the application specifically wants a short-range inductive pickup in this form and can live with two unresolved issues at once: zero listed stock and a RoHS conflict.
Can you actually buy it for a running line?
Not from listed stock. Lifecycle is Active, but stock quantity is 0, so the immediate risk is availability, not obsolescence.
That changes the decision. For a new build, don't release E2E-C06S02-WC-B2 5M onto a schedule that assumes shelf stock. For existing production, secure supply first and then decide whether the line can wait. RoHS also stays open: one field says RoHS Compliant and another says RoHS Non-Compliant, so EU RoHS status is not settled.
And the missing details are the ones that close the review
And those gaps are concrete. E2E-C06S02-WC-B2 5M is missing the pinout or wire color assignment, the cylinder drawing, and cable details beyond Cable Leads.
Wrong for long standoff sensing
Wrong for long standoff sensing and wrong for control inputs that expect another output polarity. Right for compact industrial fixtures that already want an inductive, shielded, cylindrical sensor with PNP-NC, 3-wire output and cable termination.
The 10V to 30V supply range answers one integration question and leaves another open. It places E2E-C06S02-WC-B2 5M on common industrial DC rails, but it does not give output load capability, voltage drop, or leakage, so PLC input compatibility is still unfinished from this page alone. The LED indicator helps during setup and fault finding on the machine, but it does not replace the missing output electrical limits.
View the Win-Source product page for E2E-C06S02-WC-B2 5M.
Key Takeaways for Engineers & Buyers
- Lock the control input to PNP-NC, 3-wire before releasing E2E-C06S02-WC-B2 5M.
- Check the bracket and target stackup against the 0.079" (2mm) sensing distance.
- Do not schedule a build from house stock; listed quantity for E2E-C06S02-WC-B2 5M is 0.