10V ~ 30V, 2mm shielded inductive cylinder, 3kHz, IP67, NPN-NO 3-wire, -25°C ~ 70°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Not for long range or loose mechanics
If you need generous target clearance, this is the wrong sensor. The listed sensing distance is 0.079" (2mm), which rules out fixtures that wander, thick guards, or brackets that stack tolerance on tolerance.
It fits tight industrial detection at short stand-off: shielded inductive sensing in a cylinder body, stainless steel construction, IP67 ingress protection, and cable leads for direct machine wiring. Active lifecycle keeps it in play for new design-in, but the RoHS picture is unresolved. One field says RoHS Compliant and another says RoHS Non-Compliant.
3kHz is the number that keeps fast tooling honest
3kHz is the separator here. It puts this sensor on moving equipment where slower prox switches start missing edges, but it says nothing about output loading, cable-induced distortion, or timing margin beyond that listed response figure.
The 10V ~ 30V supply range fits common industrial rails, though it remains only the allowed supply window. It does not answer brownout behavior or surge tolerance. The -25°C ~ 70°C operating temperature and IP67 rating point to plant-floor exposure, washdown splash, and outdoor-adjacent enclosures, not use beyond those ceilings.
The real fit is compact machine sensing, not general-purpose detection
The constraint is mechanical discipline. A 2mm sensing distance leaves little room for bracket tolerance, target runout, and assembly variation, and that matters more here than the stainless steel body or the LED indicator because the gap disappears fast once the stack-up gets real.
That makes this sensor a fit for repeatable metal-target positions such as end-of-travel confirmation, small fixture presence checks, or guarded stations where the target lands in the same place every cycle. The shielded construction helps when a cylindrical sensor has to mount close to surrounding metal, and the NPN-NO, 3-Wire output steers it toward control schemes already built for sinking sensor outputs.
Get the interface wrong and the failure is immediate. The PLC input scheme, not the sensor body, becomes the integration problem. Cable leads push it toward fixed machine wiring rather than quick field replacement built around detachable connectors, which matters if maintenance depends on fast swap-outs at the sensor head even with the environmental rating in good shape.
Zero stock is the buying problem
Weak point first: listed quantity is 0. Strong point second: lifecycle is Active, so this is not an obsolescence call.
Treat supply as a scheduling issue, not a redesign trigger.
What the listing still does not answer
What would a buyer ask first before sign-off? Pinout detail, a mechanical drawing, and target-dependent sensing conditions are absent here. On a 2mm inductive sensor, those details decide mounting, wiring, and whether the real target matches the stated distance.
This page also does not list load or output current limit, so the output-side interface cannot be closed from this information alone.
View the Win-Source product page for E2E-C06S02-WC-C1 5M.
Key Takeaways for Engineers & Buyers
- Match the input card to NPN-NO, 3-Wire before releasing E2E-C06S02-WC-C1 5M.
- Hold layout to a 2mm sensing target; this sensor does not buy much mechanical slack.
- Resolve the RoHS conflict before using E2E-C06S02-WC-C1 5M on a compliant build.