Omron E2E-C1C1 10M discontinued for sustaining only

E2E-C1C1 10M Omron product image

10V to 30V supply, 1mm shielded inductive range, 3kHz response, IP67 cylinder for existing production only

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 1MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V
Reported stock0 pcs reported — confirm on RFQ

Wrong for new builds, usable only where the mount is already fixed

Don't start a new machine around this sensor. The lifecycle is Discontinued, inventory is 0, and the only defensible use is existing production where sensing geometry, cable routing, and control input are already qualified.

It still fits a narrow sustaining role: a shielded inductive cylinder with 0.039" (1mm) sensing distance, NPN-NO 3-wire output, and cable leads. That combination can make a like-for-like mechanical fit more important than the lifecycle headache. EU RoHS is claimed, but the RoHS fields conflict, so compliance stays unresolved.

Can you actually buy it?

Can you actually buy it? No. Stock is 0, and the part is marked Discontinued.

If it sits on a released BOM, quarantine remaining internal stock and tie each build to a specific unit count.

1mm is the number that decides whether this sensor belongs

1mm is the decision point. The listed sensing distance is 0.039" (1mm), and that is not a casual operating gap; it is a hard fit constraint that drives bracket tolerance, target repeatability, and how quickly contamination or vibration turns detection into nuisance trips.

The 10V to 30V supply range settles a different question. It places the sensor on common industrial DC rails, but it says nothing about output current, voltage drop, or load margin at the PLC input, and those are the numbers that decide whether an interface that looks fine on paper will switch the real load reliably over time.

Then there is the 3kHz response frequency. Useful, yes. But it is still a ceiling on switching speed, not proof that the rest of the installation can take advantage of it once wiring, controller scan behavior, and the actual target motion are in play. Add IP67 and a nickel-plated brass cylindrical body, and the picture is clear: this is a compact machine sensor for very close-in metal detection, not a long-reach presence sensor and not a forgiving retrofit when the target stand-off is still moving around.

The missing electrical details are the real blocker now

And that's the real blocker. The part still needs the pinout or lead assignment, the output current limit, and the mechanical drawing before you can close a real review; without them, the PLC interface and mounting check stay open.

The listing also stops at NPN-NO, 3-wire for load-side switching detail. On a sensor with only 1mm range, wiring definition and the mechanical drawing decide success just as much as the sensing distance.

View the Win-Source product page for E2E-C1C1 10M.

Key Takeaways for Engineers & Buyers

  • Freeze the 1mm target geometry before touching E2E-C1C1 10M; that short range leaves little mechanical slack.
  • Check the control input against NPN-NO, 3-wire output and the 10V to 30V supply window.
  • Stop line planning on E2E-C1C1 10M now; stock is 0 and lifecycle is Discontinued.