Omron E2E-C1C1-5M discontinued, sustaining use only

E2E-C1C1-5M Omron product image

10V ~ 30V supply, 1mm sensing distance, 3kHz response, cylinder body, -25°C ~ 70°C limits the fit

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 1MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

Sustaining only, not a new build

Don't design this in.

The lifecycle conflict between EOL and Discontinued does not rescue E2E-C1C1-5M for new work; the conservative reading is the only safe one. That leaves one sensible use case: keeping an existing production line or service stock alive for a short interval while you sort out the next approved sensor.

The compliance picture is messy too. One field says RoHS Compliant, another says RoHS Non-Compliant, so EU RoHS status is unresolved, not favorable.

The 1mm reach is the real application filter

The constraint is mechanical first. A sensing distance of 0.039" (1mm) is a hard fit decision: this sensor belongs where the target can be held very close and repeatably to the sensing face, and it does not belong in layouts that rely on generous approach tolerance, bracket drift, or target wobble.

The 10V ~ 30V supply range answers a different question. It places the sensor on common industrial control rails inside that window, but it does not settle output loading, voltage drop, or noise margin at the receiving input. The 3kHz response frequency is fast enough to matter for counting or position feedback, yet it remains a listed ceiling; without switching waveforms or load conditions, edge behavior on the real machine is still open.

3kHz helps, but the package defines the install

3kHz matters only after the mechanics are right. The shielded inductive construction and cylinder body point toward tight industrial mounting where nearby metal would otherwise distort the field, while the nickel-plated brass body and IP67 rating fit washdown or dirty-enclosure duty better than an open sensor would.

Termination is the catch. Cable leads work when the harness path is fixed and the sensor stays put; they are less attractive where quick replacement, connector standardization, or panel-side service time drives the maintenance plan. The LED indicator helps during setup and fault finding, but it does not fill in the missing electrical details.

Can you actually buy enough?

Can you get enough to matter?

Only 1 unit is listed. For E2E-C1C1-5M, that means emergency support only, not a planned build.

What the listing still doesn’t tell you

10V ~ 30V is not enough to close the review. For E2E-C1C1-5M, the missing items are the ones that decide whether a running line can absorb it without surprises: pinout, cable lead assignment, and the mechanical drawing for the cylinder body and mounting details.

The electrical gaps matter just as much. There is no output current figure, no leakage or residual voltage detail for the NPN-NO, 3-Wire output, and no load condition tied to the 3kHz response frequency, so PLC input compatibility and switching margin cannot be judged from this page alone, especially when a 1mm sensing distance leaves little room for setup error or fixture variation.

The listing also omits any dimensional tolerance around the 0.039" (1mm) sensing distance. That's exactly the detail that separates a stable setup from nuisance trips in a close-coupled fixture.

View the Win-Source product page for E2E-C1C1-5M.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases for E2E-C1C1-5M; lifecycle is Discontinued.
  • Reserve the listed 1 unit only for an existing build stop or field repair.
  • Check the 10V ~ 30V rail and NPN-NO, 3-Wire input before touching a running line.