Omron E2E-CR6B1 2M discontinued, sustaining use only

E2E-CR6B1 2M Omron product image

0.6mm sensing, 10V to 30V supply, PNP-NO 3-wire, IP66 cylinder, -25°C to 70°C ceiling

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUCT 0.
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

Still usable only if the line already depends on it

And that is the whole call: sustaining only. Discontinued appears twice, an EOL signal sits alongside it, and stock is 1. EU RoHS is unsettled too, with one field saying compliant and another non-compliant.

Can you actually keep building with one left?

Can you actually keep building with one left? No, unless this is a stopgap for an existing production line. Stock quantity is 1, while every lifecycle signal points to discontinued or EOL wording. That combination does not support a supply plan; it supports a last-unit repair, a line-down spare, or a short bridge while the next sensor is qualified.

The fit is tight before supply even enters the discussion. The sensing distance is 0.024" (0.6mm), and that number is a hard limit for target position and bracket tolerance, not a working gap with room to spare. The supply range is 10V ~ 30V, so it belongs on control rails already inside that window, while the PNP-NO, 3-Wire output fixes the input-card type and wiring convention. Miss any one of those and the result is straightforward: missed detection, wiring mismatch, or a sensor that does not land in the existing harness.

Buy only against a named build or service need. E2E-CR6B1 2M is not inventory you can count on.

The 0.6mm limit is what makes or breaks the fit

The constraint is physical first. A 0.024" (0.6mm) sensing distance puts this sensor in very close-range metal detection, where fixture repeatability and target approach matter more than placement freedom. Shielded construction keeps the sensing field controlled around the cylinder body, so it fits dense machine hardware where side response would be a problem, not a loose setup that needs generous pickup distance.

The 2kHz response frequency supports fast events, but only after the gap and target geometry are under control. IP66 and a stainless steel body suit washdown splash and general industrial exposure, while -25°C ~ 70°C is the listed operating ceiling and floor, not proof of every ambient condition around a hot machine enclosure. Cable leads help in fixed wiring runs; they are less convenient when the build expects a connectorized sensor swap.

The missing details are the ones that close the review

Not enough here.

The body dimensions and mounting drawing are missing, so bracket fit cannot be closed from this page. Load current, voltage drop, and leakage details for the PNP-NO output are also absent, and those are the numbers that decide PLC input compatibility.

There is no pinout beyond 3-wire wording, no cable conductor assignment, and no target-size or hysteresis detail for the 0.024" (0.6mm) sensing spec. Those are not minor omissions on a sensor this short-range.

View the Win-Source product page for E2E-CR6B1 2M.

Key Takeaways for Engineers & Buyers

  • Reject new builds; E2E-CR6B1 2M is discontinued and stock shows 1.
  • Check the target gap first: 0.024" (0.6mm) is the sensing limit that decides the fixture.
  • Resolve the RoHS conflict before release: one field says compliant, another says non-compliant.