10V to 30V supply, 1.8mm sensing, 3kHz response, IP67 cylinder; lifecycle and RoHS both need caution
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Box |
| Core function | SENSOR PROX INDUCT 1. |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
1.8mm decides this part before anything else
1.8mm is the deciding number. It makes E2E-CR8C1-M5 either usable or pointless, because that sensing distance is a hard fit question for metal target geometry and mounting tolerance, while leaving little room for casual bracket changes or target drift in service.
The other early limit is the 10V ~ 30V supply range. That settles rail compatibility for common industrial control voltages, but it says nothing about noise immunity, surge behavior, or brownout behavior because those limits are not listed here. This part belongs in a machine that already expects a short-range shielded inductive sensor, not in a fresh layout where sensing margin still has to be found experimentally.
The weak point is lifecycle, not the enclosure
Discontinued is the problem. Stainless steel body, IP67, and a cylindrical shielded construction all suit coolant, chips, and close metal mounting, but none of that rescues E2E-CR8C1-M5 for a new release.
For a running line, the buy constraint is simple: stock is 1. That is not a buffer; it is a sample. Freeze demand to service needs only, and do not let E2E-CR8C1-M5 enter any new maintenance kit without a migration path attached. EU RoHS is not clean here either, because one field says compliant and another says non-compliant.
3kHz is fast enough only after the wiring matches
3kHz sounds generous until the output type narrows the job. E2E-CR8C1-M5 is NPN-NO, 3-Wire with connector termination, so the real design question is not abstract sensor speed but whether the receiving input card, harness, and machine logic already expect that switching behavior and that connection style, because if they do not, the sensor is electrically wrong even when the sensing distance and package are mechanically right.
The listed limits help, but only up to a point. The 10V ~ 30V supply range sets the allowable control rail ceiling and floor within that band, and the -25°C ~ 70°C operating temperature sets an industrial ambient envelope rather than benign bench use. What those numbers do not close is just as important: there is no listed output current limit, no voltage drop, and no short-circuit behavior, so PLC loading and fault response remain open questions even when the basic fit looks straightforward.
The LED indicator helps during setup and fault finding on the machine. It does not tell you whether the PLC input sees a clean state change at cable length or under load. Use E2E-CR8C1-M5 where the machine already uses a connectorized cylindrical inductive sensor, needs shielded mounting, and only asks for 1.8mm reach. Keep it out of any design that still needs output-interface freedom, longer sensing standoff, or compliance certainty.
The missing details are the ones that close risk
Several closing details are absent. No pinout. No mechanical drawing. No output current limit. No switching diagram.
Those gaps decide connector compatibility, bracket reuse, PLC loading, and field wiring without guesswork. One more gap matters because the compliance fields disagree: the manufacturer RoHS declaration is not settled by this listing.
View the Win-Source product page for E2E-CR8C1-M5.
Key Takeaways for Engineers & Buyers
- Stop new BOM releases with E2E-CR8C1-M5; lifecycle is Discontinued.
- Match the control input to NPN-NO, 3-Wire before touching the harness.
- Use E2E-CR8C1-M5 only where 1.8mm sensing distance is already proven in the machine.