10V ~ 30V supply limits, 10mm sensing distance, M30 threaded body and PNP-NO cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 10MM PNP M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a PNP-NO design-in
An input expecting a different output can't use this PNP-NO, 3-Wire sensor. That constraint comes first. E2E-X10B1D30 2M is Active in both lifecycle and product status, so new design-in is reasonable where the interface fits. The listed 10V ~ 30V supply limits screen rail compatibility; they do not establish what load the output can drive. EU RoHS compliant.
Cable leads put the assembly decision on the line
That Active status also supports sustaining designs, but cable leads rather than a listed connector leave termination to be defined in the assembly instructions before machine wiring is fixed. The listed box package doesn't settle that operation.
The M30 sensor fits a metal-target station, not every input
Wrong for an input expecting a normally closed state, E2E-X10B1D30 2M belongs at a metal-target station wired for its PNP-NO output. The listed 10mm sensing distance guides target spacing, but it does not guarantee detection for every target or mounting arrangement. The shielded, M30 threaded body gives the fixture designer a mounting starting point, while the nickel-plated brass body and IP67 and IP69K ratings identify the construction and ingress protection being selected.
The listed 400Hz response frequency is a ceiling for event-rate selection, not a promise that a brief target pulse will register. The -40°C ~ 85°C operating-temperature range bounds the temperature decision, but it cannot establish the temperature inside a heated enclosure. Get either decision wrong and the machine may miss targets despite a sensor that mounts and wires cleanly.
The 10mm claim still needs mounting detail
10mm cannot settle fixture clearance without a mechanical drawing. Cable-lead assignments and an output-load rating are also absent from the listing; the manufacturer's datasheet must supply both before the wiring is fixed. The sensing-distance figure cannot answer those questions.
View the Win-Source product page for E2E-X10B1D30 2M.
Key Takeaways for Engineers & Buyers
- Check target spacing against the listed 10mm sensing distance.
- Keep event rates within the listed 400Hz response frequency.
- Reserve an M30 threaded mount and define cable-lead termination.