10 mm sensing distance, 10V to 30V supply, threaded M30 body, and PNP-NC cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 10MM PNP M30 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
PNP-NC sensing is the case for a new design-in
An NPN input or a normally open sequence rules this sensor out. It belongs at a machine input expecting a PNP-NC, 3-wire inductive signal from a threaded M30 body. The shielded construction and nickel-plated brass body are consistent with machine mounting, but don't tell you where the sensing face can sit relative to the target.
Lifecycle and product status both read Active, supporting new design-in on the listed status. EU RoHS compliance is listed too. Neither fact changes the electrical fit: get the input logic wrong and the machine sees the wrong state.
10 mm reach is not permission to ignore speed or supply
10 mm is the listed sensing distance. Use it to judge reach against the target path, not as a promise for every target material or mounting arrangement. The 10V to 30V supply range bounds the power source choice; it says nothing about output load capacity. That matters if the input circuit needs more than a signal-level connection.
The listed 400Hz response frequency is the speed figure to compare with passing targets, but it doesn't prove that every brief passage of a target will register. The operating temperature range of -40°C to 85°C bounds the stated environment; heat at the installed sensing face or cable exit remains a separate question. IP67 and IP69K are listed ingress ratings; installed cable routing still has to preserve the intended seal.
Cable leads are the purchasing constraint
Will the running machine take cable leads? E2E-X10B230 5M has cable leads, not a listed connector termination. Keep that termination and PNP-NC wiring in the assembly specification when ordering for existing production; changing either changes the installation.
The M30 mounting and output circuit still need drawings
Which leaves details the ratings cannot settle. The mounting drawing is absent, so M30 alone cannot establish the installed clearance or sensing-face position. The wiring diagram and output load-current limit are also absent; those are needed to connect and load the PNP-NC output correctly. A target-material correction curve would close the remaining question behind the listed 10 mm reach.
View the Win-Source product page for E2E-X10B230 5M.
Key Takeaways for Engineers & Buyers
- Match the PNP-NC, 3-wire output to the machine input.
- Check the target path against the listed 10 mm sensing distance.
- Keep cable leads in the assembly specification; obtain the mounting drawing before release.