10 mm sensing distance, 10V–30V supply limits, and an M30 threaded body with PNP-NC output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 10MM PNP M30 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Can this Omron sensor go into a new machine build?
Can I specify it for a new machine build? Yes, if the controller expects a PNP-NC, 3-wire inductive sensor. Omron E2E-X10B230-R 5M is marked Active across its lifecycle fields, with no stated conflict; its status does not restrict it to sustaining designs. Assign the NC output deliberately, or the machine will act on the opposite target state. EU RoHS compliance is listed.
The supply and temperature limits set the installation envelope
Supply voltage and ambient temperature set the installation limits. The listed 10V–30V range defines the permissible voltage at the sensor, not a preferred rail; voltage outside either bound is out of range. The -40°C to 85°C operating-temperature range defines the ambient boundaries, with 85°C as the upper ceiling. Neither endpoint is a target condition.
The listed 400Hz response-frequency figure can help screen a repetitive target application, but it specifies neither switching delay nor minimum dwell time, so a fast-moving feature still calls for timing detail before controller logic is fixed. The LED can indicate state; it can't establish that the sensor catches every passing target.
10 mm reach has to work in an M30 mount
10 mm is the listed sensing distance, not a guaranteed switching gap for every metal target. Set the target path and bracket position around the sensing task before committing the M30 threaded mount. The shielded inductive construction belongs at a machine-mounted metal target, not in a board-level sensing footprint. IP67 and IP69K are listed for ingress protection; neither establishes suitability for a particular cleaning chemical.
Cable leads are the assembly decision
Box packaging says little about installation effort; cable leads determine the assembly work. Define their termination before releasing assembly instructions. Don't assume a connector at the sensor: that would leave the wiring station with the wrong termination.
The sensing and mounting details still missing
10 mm alone cannot settle target placement. The listing lacks target-material correction and hysteresis information, an M30 mounting drawing, and cable conductor assignment. Get those details from the datasheet before releasing the bracket and wiring.
View the Win-Source product page for E2E-X10B230-R 5M.
Key Takeaways for Engineers & Buyers
- Keep voltage at the sensor within the listed 10V–30V supply limits.
- Map the PNP-NC, 3-wire output to the intended controller input polarity.
- Set target placement against the listed 10 mm sensing distance.