Omron E2E-X10B3D30 2M: Active for new designs

E2E-X10B3D30 2M Omron product image

10 mm sensing distance, 10 V to 30 V supply, M30 body and -40°C to 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 10MM PNP M30 NO/NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

The 10 mm sensing distance is the first design-in test

10 mm is the listed sensing distance, not a promise that every metal target will trip at that gap; check the actual target and mounting position before release. The body is shielded. Its M30 thread points toward machine-mounted detection, but the listed distance alone cannot fix its mounting position. Omron E2E-X10B3D30 2M is Active across the recorded lifecycle fields, with no stated lifecycle conflict for new design-in or existing production. EU RoHS compliance is listed.

A 400 Hz entry does not settle fast-event detection

A fast pulse train is the wrong job if detection depends on switching timing: the 400 Hz response-frequency entry doesn't define that timing. For a fixed position on industrial machinery, the M30 threaded body and cable leads offer a physical starting point. The 10 V to 30 V supply range sets the rail boundaries, not a preferred setpoint; a rail outside that range rules the part out. The -40°C to 85°C operating range bounds the temperature choice but says nothing about cable exposure or mounting clearance.

Will the M30 body and cable leads work on the running line?

Will the M30 body fit the mounting point, and can the line terminate its cable leads? For E2E-X10B3D30 2M, those are buying constraints: put the exact model and termination style on the purchase specification. A sensor that fits but can't be wired by the established build process can stop assembly. Box is the stated packaging format, not a connector choice.

The 3-wire PNP-NC/NO output must also match the control input and required switching sense. Set that interface before release; an M30 body does not make sensors electrically interchangeable. For existing production, keep the specified connection and mounting arrangement tied to the exact model rather than treating the package description as sufficient.

The PNP label leaves the wiring and load unresolved

The electrical detail is thin. The 3-wire PNP-NC/NO entry still identifies the interface family. An output-load rating and wiring diagram are absent; both matter before assigning the control input. The mounting drawing is absent too, so M30 alone cannot close physical clearance.

View the Win-Source product page for E2E-X10B3D30 2M.

Key Takeaways for Engineers & Buyers

  • Check the 10 mm detection point against the actual target and mounting position.
  • Match the 10 V to 30 V supply range to the machine rail.
  • Specify M30 threaded mounting and cable leads on the build record.