Omron E2E-X10B3D30-M1: Active for New Designs

E2E-X10B3D30-M1 Omron product image

10mm sensing distance, 10V to 30V supply limits and an M30 threaded body set the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 10MM PNP M30 NO/NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

Active status makes this M30 sensor a new-design candidate

So E2E-X10B3D30-M1 stays in contention for new designs, provided the machine can use a shielded inductive sensor with a threaded M30 body. Both lifecycle and product status say Active. Its PNP-NC/NO, 3-wire output must also suit the controller input scheme; the output label alone does not settle the wiring.

EU RoHS compliance is listed. That answers one compliance question, not whether the sensor will detect the intended target at the required position.

The 10mm reach needs a real target check

The listing gives no target-dependent sensing data, but it does give a 10mm sensing-distance ceiling. That is not permission to place every target 10mm from the face. Where clearance is tight, test the intended target before fixing the bracket position.

The 10V lower supply bound and 30V upper ceiling define the supply range, but neither specifies how the sensor behaves on a marginal rail. The −40°C to 85°C operating range sets the temperature bounds, with 85°C as the upper ceiling, but it does not establish the temperature at the installed sensor. The LED cannot settle these questions. A missed target or an out-of-range supply stops the input from doing its job.

Will the M30 connector fit the running machine?

Will it fit the existing mount and cable? The threaded M30 body and connector termination must match the production line before the sensor goes on the BOM. Box packaging cannot settle either fit.

400Hz does not settle the switching check

400Hz is the listed response-frequency ceiling. It doesn't promise a usable controller signal for every moving target. Target-dependent sensing data is missing, as are the connector pinout and dimensional drawing. Those gaps leave detection distance, wiring and mounting unsettled; M30 names the thread but does not close the mounting check.

View the Win-Source product page for E2E-X10B3D30-M1.

Key Takeaways for Engineers & Buyers

  • Test the intended target against the listed 10mm sensing-distance ceiling.
  • Keep the sensor supply within its 10V to 30V listed bounds.
  • Obtain the connector pinout before wiring the PNP-NC/NO output.