Omron E2E-X10C130 2M: Active for new designs

E2E-X10C130 2M Omron product image

10mm sensing distance, 10V–30V supply bounds, M30 threaded body and -40°C to 85°C operating range

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 10MM NPN M30 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

An inductive M30 sensor is the wrong tool for nonmetal targets

Nonmetal targets rule out this inductive sensor. For metal targets on industrial equipment, the shielded M30 threaded body gives E2E-X10C130 2M a defined mounting format. The listed 10mm sensing distance is a spacing ceiling, not a guaranteed switching point for every target; a mount that cannot bring the target within that distance rules it out.

The part is Active, with no conflict among its lifecycle signals. New design-in is reasonable if the installation fits. It is listed as compliant with EU RoHS.

The supply and temperature bounds set the cabinet limits

Supply and temperature limits bound the cabinet fit. The listed supply range is 10V to 30V; 30V is a ceiling, not a working setpoint. The operating-temperature range is -40°C to 85°C, with 85°C as its ceiling. A supply outside those bounds fails the fit check, and neither range establishes margin at the installed location.

The NPN output and 400Hz limit decide the input path

The input path is specific. E2E-X10C130 2M has an NPN-NO, 3-wire output, and the receiving input must accept it. The M30 thread cannot make a different output type compatible. The listed 400Hz response frequency is a switching-speed ceiling for screening the application; it isn't a switching-time specification or proof that a particular passing target will register.

The 10mm sensing distance helps place the sensor and metal target, but the actual switching distance still depends on the target and geometry. Cable leads make this a wired installation rather than a connector swap. IP67 and IP69K are listed ingress ratings for the sensor; neither defines how the far end of the leads is protected.

Cable leads make the missing drawing matter

The installation detail is the weak point, not the Active lifecycle status. Cable leads make the drawing a purchasing constraint: obtain it before committing to routing or termination. There is no wiring diagram to assign conductors, no dimensional drawing to check mounting clearance, and no target-material correction data to close the 10mm spacing check. Physical and electrical fit remain open even when the listed ratings look right.

View the Win-Source product page for E2E-X10C130 2M.

Key Takeaways for Engineers & Buyers

  • Check the metal target and mounting geometry against the 10mm sensing distance.
  • Match the input circuit to the NPN-NO, 3-wire output.
  • Obtain the cable drawing before fixing the routing and termination.