10mm sensing limit, M30 body, 10V ~ 30V supply range and -40°C ~ 85°C operating temperature
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 10MM NPN M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Is the E2E-X10C1L30 2M a new-design candidate?
Can it go into a new design? Yes. Its lifecycle signals agree on Active, with no stated lifecycle reason to restrict it to sustaining designs. EU RoHS compliance is listed. Cable-lead termination, rather than a plug connection, belongs in the build plan before BOM release.
The 10mm limit puts target placement first
10mm is the listed sensing-distance limit, not a guaranteed switching gap for every target. A target path beyond that ceiling rules the sensor out, even if the electrical output matches the controller. The shielded, threaded M30 body provides a defined mounting format, but it doesn't establish where the target will pass the sensing face or whether that path stays within reach. Lay out the target path and mounting position together.
The supply range and output must match the controller
The supply window sets the rail constraint: 10V is the listed lower bound and 30V the ceiling, not a suggested working setpoint. The NPN-NO, 3-Wire output must suit the controller input before sensing distance matters. The -40°C ~ 85°C operating-temperature range bounds the machine environment; 85°C is the upper limit, not an intended running temperature. The listed 400Hz response frequency sets a speed ceiling but does not establish timing for a particular target pass.
The missing interface details can still stop the installation
Installation isn't settled. IP67 and IP69K are listed, putting E2E-X10C1L30 2M on the shortlist for exposed machine locations, but neither rating tells the installer how to route its cable leads. Wiring identification and an output load-current limit are still needed to clear the terminal connections and electrical load.
The M30 thread gives a mounting format, not body length or cable clearance; those require a mounting drawing. A target-dependent sensing curve is also absent, leaving the listed 10mm reach untested against the actual target and approach geometry. These gaps can stop the sensor from being released into the machine layout despite its listed ratings.
View the Win-Source product page for E2E-X10C1L30 2M.
Key Takeaways for Engineers & Buyers
- Check the target path against the 10mm sensing-distance limit.
- Match the 10V ~ 30V supply range and NPN-NO output to the controller input.
- Plan cable-lead termination before fixing the M30 mounting layout.