10V to 30V supply, 10mm sensing distance, M30 body, -40°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 10MM NPN M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Can this Omron sensor go into a new machine?
Can this sensor go into a new machine? Yes. E2E-X10C1L30 5M is marked Active across the listed lifecycle fields, with no conflict between them. It supports new design-in where the electrical interface and mounting fit. EU RoHS compliance is listed.
Cable leads make termination a layout decision, not one to defer until assembly. Put the cable route and termination method on the build drawing before releasing the machine layout.
The NPN-NO output decides the controller input
The NPN-NO, 3-wire output is the catch: it won't suit a controller input expecting a sourcing signal. The listed 10V to 30V supply range brackets the rail choice, but it says nothing about the load the output can drive, so match the input circuit before settling the mount. A correct mounting hole cannot rescue the wrong signal polarity.
The sensor has a nickel-plated brass body and listed IP67 and IP69K ratings. Those ratings don't establish resistance to the machine's particular cleaning chemicals. The LED indicator can help at the machine, but it cannot resolve electrical compatibility.
10mm sensing still needs an M30 mounting plan
10mm is the listed sensing distance, not a target position to treat as a guaranteed detection point. Set the target path and mounting adjustment around the distance the application needs. The shielded, threaded M30 cylinder calls for a fixed machine mount, not a narrow bracket chosen after the layout is set.
The -40°C to 85°C operating-temperature range bounds where that mount can go. It gives no account of how sensing distance changes across the range, leaving temperature-sensitive target placement open.
400Hz does not settle target timing
400Hz is the listed response-frequency ceiling, not a switching waveform. It cannot settle detection of the machine's moving targets on its own. Switching hysteresis, output load-current limits, a pinout and a mechanical drawing are absent; obtain those datasheet items to close timing, wiring and mounting before release.
View the Win-Source product page for E2E-X10C1L30 5M.
Key Takeaways for Engineers & Buyers
- Match the controller input to NPN-NO, 3-wire switching.
- Keep the rail within the listed 10V to 30V supply limits.
- Reserve an M30 threaded mount and route the cable leads.