Omron E2E-X10C2L30 5M: Active, with a defined fit

E2E-X10C2L30 5M Omron product image

10mm sensing distance, 10V ~ 30V supply limits, M30 body, -40°C ~ 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 10MM NPN M30 NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new M30 sensor build

New design-in is reasonable. E2E-X10C2L30 5M is listed Active in both lifecycle and product status, with no status conflict, provided the machine matches its mounting and output. EU RoHS compliance is listed.

This shielded inductive sensor has an M30 threaded body and cable leads. It fits a mounted metal-target detection point, not a bracket drawn for a different body or a harness expecting a connector.

Will the M30 mount and NPN-NC output match the machine?

Will it fit the bracket and controller input? The M30 threaded body sets the mounting geometry, while the NPN-NC, 3-wire output determines whether the controller input and its expected normal state match at the machine. Get the output sense wrong and the machine can read a clear target path as occupied.

The listed 10mm sensing distance does not establish detection at every mounting position or for every metal target. Check the target’s actual path before fixing the bracket. The 10V ~ 30V supply limits bound the rail choice; they do not select a nominal supply. The -40°C ~ 85°C operating range gives an ambient-temperature fit check, but heat at the installed sensor still matters. IP67 and IP69K are listed ingress ratings; the cable installation must preserve the intended protection.

Cable leads set the line-build constraint

The M30 body and cable leads constrain the station layout. E2E-X10C2L30 5M won’t drop into a connectorized station unchanged. Set the termination method in the harness instructions and route the cable before committing the sensor position. The listed package is a box, not a connector option.

400Hz does not close the timing check

400Hz is the listed response-frequency ceiling. It can rule out a detection scheme that needs a faster response, but it is neither a switching waveform nor a guaranteed result for every target passage. It can’t settle the controller’s timing check alone.

The listing lacks a pinout, a mechanical drawing, and target-dependent sensing-distance curves. Those gaps affect the harness connections, bracket clearance, and detection margin before E2E-X10C2L30 5M goes onto a released machine drawing.

View the Win-Source product page for E2E-X10C2L30 5M.

Key Takeaways for Engineers & Buyers

  • Check the target position against the listed 10mm sensing distance.
  • Match the controller input to the NPN-NC, 3-wire output.
  • Get the M30 mounting drawing before fixing the bracket.