Omron E2E-X10C330 5M: Active for New Machine Designs

E2E-X10C330 5M Omron product image

10mm inductive sensing, 10V to 30V supply, M30 threaded body, -40°C to 85°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 10MM NPN M30 NO/NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

The 10mm reach makes target placement the first decision

10mm is the listed sensing distance, not a promise that every metal target can sit that far from the face. E2E-X10C330 5M is listed Active with no lifecycle conflict, so it's a candidate for new machine designs, provided the actual target and mounting position are tested before the bracket is fixed. The 10V to 30V supply bounds determine whether the control rail fits; they say nothing about tolerance of rail disturbances. Operation is listed from -40°C to 85°C, with 85°C as the upper bound. Account for heat at the installed sensor. EU RoHS compliance is listed.

The M30 body and NPN output settle much of the fit

Even with the target placed, the M30 threaded, shielded body needs a mounted sensing position, not a sensor hanging by its cable. The listed 3-wire NPN-NC/NO output suits an input built for that wiring, but does not establish the output load the sensor can carry.

Cable leads make harness routing the buying constraint

Cable routing is fixed by the leads. Specify that termination in the harness and leave room for the M30 body before releasing a new build; the listed part is not a connectorized sensor. For existing production, keep the same termination in the build instructions so a change in how the cable is landed does not stop the line.

400Hz does not close the switching or wiring questions

400Hz is the listed response frequency. It screens out applications whose event rate exceeds that figure, but does not guarantee switching time for a particular target or input circuit. Before finalizing the input, the wiring diagram needs to identify the NPN-NC/NO connections, and the output load rating needs to establish what that input may draw. The mechanical drawing is also absent. M30 alone cannot settle mounting clearance. Target-dependent sensing data would show how much of the listed 10mm distance survives with the metal actually being detected. None of that follows from the sensor's name.

View the Win-Source product page for E2E-X10C330 5M.

Key Takeaways for Engineers & Buyers

  • Test the actual target at the listed 10mm sensing distance.
  • Keep the sensor supply within the listed 10V to 30V bounds.
  • Reserve an M30 threaded mount and route the cable leads.