10mm sensing, 12V ~ 24V supply, M30 threaded body; RoHS status conflicts.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 12V ~ 24V |
Active lifecycle does not settle the E2E-X10D1-N 5M release
That still leaves a conditional verdict for a new build. Both lifecycle fields say Active, with no stated lifecycle warning for sustaining production. But the top-level entry says RoHS Compliant while the specification says RoHS Non-Compliant. RoHS remains unresolved. A new build requiring EU RoHS needs that conflict settled before release.
The 10mm reach and 400Hz response set the sensing job
A target beyond the listed 10mm sensing distance is the wrong job for this shielded inductive sensor. That figure is a limit, not a promised gap for every target. The threaded M30 body and cable leads suit a machine mounting that accommodates them; the NO, 2-Wire output must suit the receiving input.
The listed 400Hz response frequency is another ceiling. A faster event stream cannot be justified from that rating. The intended rail must also stay within the 12V ~ 24V supply range, which says nothing about output behavior under load.
Can bulk cable-lead units go straight onto a running line?
Can the line handle a bulk, cable-lead sensor? That is the buying question for E2E-X10D1-N 5M. Set an assembly method that protects the leads and accommodates the threaded M30 body before committing it to the station; the bulk package entry doesn't describe a prepared connector. The nickel-plated brass body and IP67 rating describe the listed construction and ingress-protection classification. Neither settles cable routing at the station.
The listed operating range is -25°C ~ 70°C. Keep the installed location within it; a warmer location is outside the range. The RoHS contradiction is a separate release hold. Obtain a manufacturer declaration that resolves the opposing fields rather than treating Active lifecycle status as evidence of compliance.
The 12V ~ 24V range leaves the input circuit unfinished
The 12V ~ 24V supply range leaves load compatibility open for the NO, 2-Wire output. Output leakage and on-state voltage drop are absent, yet both matter to whether the receiving input changes state reliably. The M30 designation lacks a mechanical drawing, and the 10mm distance lacks target-dependent sensing data. Resolve those gaps before fixing the input circuit and mount.
View the Win-Source product page for E2E-X10D1-N 5M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting EU RoHS fields with a manufacturer declaration before release.
- Check the target gap against the listed 10mm sensing distance before fixing the M30 mount.
- Match the NO, 2-Wire output to the input after obtaining leakage and on-state drop data.