Omron E2E-X10D1-N: Active for New Sensor Designs

E2E-X10D1-N Omron product image

10 mm sensing distance, 10 V to 30 V supply limits, M30 body and -25°C to 70°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

The M30 body rules out a compact sensor bore

A compact sensor bore rules out the M30 threaded body. A cable-lead inductive pickup on a machine bracket is the more plausible fit. E2E-X10D1-N is marked Active across the lifecycle fields, with no conflict; new design-in is reasonable, and EU RoHS is marked compliant.

The sensing gap and response rate set the limits

The limits are firm. The listed 10 V to 30 V supply bounds rule out rails outside that range; 30 V is a ceiling, not a preferred setting. The 10 mm sensing distance is a starting target gap, not proof that every metal target will switch there. The listed 400 Hz response frequency is an event-rate ceiling, not a switching-time measurement. Faster events could be missed.

The -25°C to 70°C operating-temperature range admits a machine location within those bounds but rules out a hotter one. A suitable rail and ambient won't rescue a target beyond the usable sensing gap or one passing too quickly for the listed 400 Hz response-frequency ceiling.

The NPN-NO cable output dictates the build

2-Wire NPN-NO output puts input compatibility ahead of mounting convenience: choose an input circuit that accepts this output rather than assuming it behaves like a dry contact. The shielded, nickel-plated brass M30 body gives the bracket a defined sensor format, while cable leads still need a termination plan.

Bulk packaging is the production constraint. Plan how the cable-lead sensors will be kitted and connected on the line before releasing the build.

IP67 does not settle the installed sensor geometry

10 mm is the listed sensing distance, but the absent target-material correction curve leaves the actual gap unresolved for the chosen metal target. IP67 is the stated ingress rating, not proof that the installed cable termination has the same protection. Without a mechanical drawing, bracket clearance and cable routing cannot be frozen. The wiring diagram and output leakage-current limit are also absent; both matter when selecting the input module.

View the Win-Source product page for E2E-X10D1-N.

Key Takeaways for Engineers & Buyers

  • Match the input circuit to the NPN-NO, 2-Wire output.
  • Reserve an M30 threaded mounting location and route the cable leads.
  • Check the event rate against the listed 400 Hz response-frequency ceiling.