10 V to 30 V supply limits, 10 mm sensing distance, M30 threaded body, -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Voltage - Supply: 10V ~ 30V |
A 10 mm sensing distance makes target testing the first gate
10 mm is the listed sensing distance for this shielded inductive sensor, not proof that the actual metal target will be detected. E2E-X10D15-N 2M is Active, supporting new design-in once the target is tested. It is EU RoHS compliant.
The supply range does not settle the controller connection
10 V to 30 V is the listed supply range. The 30 V figure is a ceiling; it doesn't establish that the NPN-NO, 2-wire output suits every controller input within that range. A mismatched input can leave the machine reading the wrong state. The -25°C to 70°C operating-temperature range bounds the installation, with no established headroom outside it. IP67 states an ingress classification, not how the cable end is sealed.
M30 mounting and cable leads govern the production change
Will the M30 threaded body and cable leads fit the existing fixture? This is a machine-mounted sensor, not a board-level detector. Keep the existing mount and cable route in view during the production change, because the threaded cylinder needs a mounting decision and the cable leads need a route and termination. Shielding does not replace a test of the 10 mm sensing distance against the actual target and surrounding metalwork.
The NPN-NO, 2-wire output must match the controller input; “NPN” isn't enough to settle the connection. Bulk packaging sets a receiving constraint, so arrange handling for bulk units before releasing a production build. The sensor head cannot be treated as an interchangeable shape.
Switching and mounting details still need drawings
The electrical case remains open. No switching frequency is listed, so moving-target detection cannot be settled here. No output load-current limit is listed for checking the controller interface either. A wiring diagram is needed for the 2-wire connection, and a mechanical drawing must settle mounting clearance. The M30 label alone cannot release the fixture.
View the Win-Source product page for E2E-X10D15-N 2M.
Key Takeaways for Engineers & Buyers
- Test the actual target at the listed 10 mm sensing distance.
- Match the 2-wire NPN-NO output to the controller input.
- Check M30 mounting space before releasing the fixture.