10mm sensing distance, 12V to 24V supply, M30 threaded body; test the target before design-in.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 12V ~ 24V |
10mm reach supports a new design-in, not an assumed trip point
10mm is the listed sensing distance, not a guaranteed trip point for every target. For an inductive sensor facing a metal target, Omron E2E-X10D1L 5M is a candidate only where the actual target and mounting position can be tested together. A missed target becomes a missed machine event.
Lifecycle Status and Product Status both say Active. That supports a new design-in if the sensing fit is established.
Bulk cable leads are clear; EU RoHS is not
EU RoHS status is unresolved: the compliance field says RoHS Compliant, while the specification says RoHS Non-Compliant. Resolve that conflict before purchase release. Bulk packaging and cable leads are clear, so plan assembly around a wired sensor rather than a connectorized one.
The rail and event rate narrow the machine fit
The rail range and event-rate ceiling constrain machine fit. The listed supply bounds are 12V and 24V; check the machine rail against them, but don't treat them as a preferred setpoint or a statement of the voltage left across a load on the NO, 2-wire output. The listed 400Hz response-frequency ceiling screens out applications that demand a higher event rate. It does not establish that a particular moving target will be counted reliably at that ceiling.
The -25°C to 70°C operating range rules out mounting locations beyond those bounds. An M30 threaded, shielded body gives E2E-X10D1L 5M a defined style of machine mounting, and IP67 is its listed ingress protection. Neither settles clearance around the installed cable. A fixed, threaded sensing position fits those constraints better than a location without room for the body and cable route.
A drawing and output limits still hold the release
The drawing is missing. Without dimensional and wiring drawings, the M30 opening, cable route, and NO, 2-wire connection cannot be signed off here. Target-dependent sensing information and output load limits are also absent; both are needed to establish whether the actual target trips at the listed 10mm distance and whether the connected load works with this output.
View the Win-Source product page for E2E-X10D1L 5M.
Key Takeaways for Engineers & Buyers
- Test the actual target at the listed 10mm gap.
- Check the 12V to 24V supply bounds against the machine rail.
- Resolve the conflicting EU RoHS entries before release.