Omron E2E-X10D1S-M1: EOL, for sustaining designs only

E2E-X10D1S-M1 Omron product image

10V–30V supply limits, 10mm sensing distance and M30 body; EOL status confines it to sustaining designs.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

Can this Omron sensor stay on a running line?

Can the running line keep using this sensor? Yes, for sustaining designs. Lifecycle Status marks E2E-X10D1S-M1 EOL even though Product Status says Active, so treat EOL as controlling, secure inventory for existing production and plan migration before a stopped line forces the issue. Don’t specify it for a new design.

Bulk packaging also affects handling. Match receiving and line feeding to bulk-packed, connector-terminated sensors rather than assuming they arrive as ready-to-install assemblies. EU RoHS compliance is stated, but it doesn’t change the lifecycle verdict.

What do 10mm and the supply limits decide?

10mm is the listed sensing-distance limit, not a guaranteed switching gap for every target. It bounds the mechanical layout without settling detection with the intended target. The 10V and 30V supply limits rule out a rail outside that range; they don’t establish what load the output can drive.

The M30 body and 2-Wire output narrow the fit

Mounting clearance and input compatibility narrow the fit. The M30 threaded body needs room for the cylinder and its connector. This shielded inductive sensor belongs at a metal-target detection point, but its NPN-NO, 2-Wire output must match the controller input. A mismatch can leave a sound sensor looking permanently off.

IP67 is an ingress-protection rating, not permission for every cleaning process. The -25°C to 70°C operating-temperature range bounds the installation; ambient outside it rules this part out.

Does 400Hz settle detection timing?

400Hz is the listed response-frequency ceiling. It can screen a fast target stream, but it does not establish switching behavior for the intended target and mounting position. That needs application testing.

The connector pinout, mounting drawing and output load-current limit are absent. Get those items before committing the harness and controller input; the frequency figure cannot tell you whether that input will recognize the switched state.

View the Win-Source product page for E2E-X10D1S-M1.

Key Takeaways for Engineers & Buyers

  • Treat EOL as controlling over the Active field; secure inventory and plan migration.
  • Keep the sensor rail within the listed 10V–30V supply limits.
  • Get the connector pinout and output load-current limit before committing the input circuit.