Supply-voltage, sensing-distance and temperature limits are unstated for this bulk-packed proximity sensor.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Core function | SENSOR PROX |
Active status keeps this Omron sensor in contention
2M ends the orderable identifier; it does not state a cable length. Omron marks E2E-X10D2-U 2M Active across its lifecycle fields, keeping it in contention for a new design. Active status isn't clearance: the EU RoHS entries contradict each other.
No stated limits establish sensing or electrical fit
No supply-voltage figure or unit is listed. That leaves no stated ceiling for the intended supply, while the missing sensing-distance limit leaves target placement unresolved. Response frequency and operating temperature are also unstated, so the listing cannot establish whether the sensor will respond fast enough or tolerate its installed environment. Don't infer operating limits from the part number.
Can bulk-packed units enter the running line?
Can these bulk-packed units enter the running line? First establish whether they are the sensor the line has qualified. The industrial proximity-sensor category identifies its broad job, and Bulk describes its packaging; neither establishes output type, termination or housing. For a line already built around this orderable identifier, the decision is narrower than it would be for a new installation: retain the approved configuration and resolve the conflicting EU RoHS entries before further release.
For a new installation, hold the BOM decision. Without an output type, the controls interface cannot be checked; without a termination style, the wiring plan cannot be closed. Active status answers neither question. Obtain the exact sensor specification and a compliance declaration tied to E2E-X10D2-U 2M before treating it as qualified for the build.
The drawing and sensor curves still have work to do
And the mount remains open. A housing drawing and termination details are needed before the mount and connection can be approved. The sensing-distance specification must identify the conditions behind that limit; no such figure is listed. Ingress protection is also unstated, leaving the housing's fit for the installed exposure unresolved.
View the Win-Source product page for E2E-X10D2-U 2M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting EU RoHS entries before release.
- Obtain supply-voltage and sensing-distance limits before selecting the sensor.
- Check the termination and housing drawing against the intended mount.