Omron E2E-X10E2-M1: Discontinued, for sustaining only

E2E-X10E2-M1 Omron product image

10mm sensing distance, 10V ~ 40V supply, M30 threaded body; sustaining designs only.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCT 10MM IP68 CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 40V

The 10mm reach does not justify a new design-in

10mm is the listed sensing distance, not a guaranteed gap for every target. E2E-X10E2-M1 is for sustaining designs only: one lifecycle signal says EOL, and both status fields say Discontinued. Don't design it in; plan migration for existing production.

Can a running line still use the M30 sensor?

Can I keep a running line supplied? Secure parts for existing production, but check the installed position against the NPN-NC, 3-Wire output and M30 threaded cylinder before treating the sensor as a fit. It ships in bulk, so account for that handling format. The listing states EU RoHS compliance without a revision or exemption detail.

The 400Hz figure screens events, not switching delay

The 400Hz response frequency doesn't specify switching delay, but it gives a figure to compare with the machine's event rate. A mismatch can mean missed detections. The shielded inductive sensor and IP68 ingress rating merit a look for an existing industrial sensing position, but neither confirms the listed 10mm reach for the installed target.

40V is a ceiling; wiring and target fit remain open

40V is the listed supply ceiling, not a working setpoint. Before changing hardware, compare the 10V lower bound and -40°C ~ 85°C operating-temperature range with the machine's supply and temperature conditions, then check the installed target gap against the sensing data. Those limits can rule out an electrical or temperature mismatch, but they do not establish detection at that gap.

The listing has no connector pinout or mating-connector detail, so the NPN-NC, 3-Wire description cannot settle the wiring check. It also lacks a mounting drawing and target-dependent sensing curves. Get those items before treating the M30 body and 10mm sensing distance as proof that the sensor will fit the existing station.

View the Win-Source product page for E2E-X10E2-M1.

Key Takeaways for Engineers & Buyers

  • Check target clearance against the listed 10mm sensing distance.
  • Compare the 400Hz response frequency with the machine's event rate.
  • Plan migration before relying on E2E-X10E2-M1 for existing production.