Omron E2E-X10F1 10M: Discontinued, for sustaining only

E2E-X10F1 10M Omron product image

10mm sensing, 10V ~ 40V supply limits, M30 threaded body; discontinued.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCT 10MM CYL 10M
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 40V

A discontinued M30 sensor is not a new-design choice

A new machine is the wrong place for E2E-X10F1 10M. The lifecycle parameter says EOL, while both status fields say Discontinued; despite the different wording, neither supports using this part in a new design. Keep it for sustaining designs that already use its M30 threaded body and cable leads. A change to the bracket or wiring takes work that the electrical ratings cannot settle. Listed EU RoHS compliance does not change the lifecycle call.

The 10mm reach needs a target, not an assumption

10mm is the listed sensing distance for this shielded inductive sensor. It does not establish where a particular target will switch in a particular mount, so check the existing target and bracket before calling the sensor a drop-in fit. The 10V ~ 40V supply limits set a 40V ceiling and a 10V lower bound; they rule out a rail beyond those limits but say nothing about allowable ripple or output loading.

The listed 400Hz response frequency helps screen moving-target applications. It isn't a switching-time guarantee and cannot, on its own, establish whether a brief target pass will register. The PNP-NO, 3-Wire output must also match the controller input. A bracket match alone will not keep the line running.

Can an existing line keep buying this sensor?

Can we keep buying E2E-X10F1 10M for the existing line? The M30 body, cable leads and PNP-NO output define what must stay compatible. Its IP68 rating and -40°C ~ 85°C operating-temperature range support a check against the installed environment, but neither resolves the discontinued status. Secure inventory for existing production and plan migration rather than specifying it on a new machine.

The M30 fit still needs a drawing

That still leaves a practical gap. Without a mounting drawing or pinout, the threaded-body description cannot settle bracket clearance or cable connections. An output-load rating is also missing, leaving the controller interface unchecked.

View the Win-Source product page for E2E-X10F1 10M.

Key Takeaways for Engineers & Buyers

  • Keep E2E-X10F1 10M off new-design BOMs; plan migration for existing production.
  • Check the 10mm sensing distance against the actual target and mounting position.
  • Obtain the M30 mounting drawing before changing the sensor bracket.