Omron E2E-X10F1: Discontinued, for sustaining designs only

E2E-X10F1 Omron product image

10 mm sensing distance, M30 threaded body, 10 V to 40 V supply limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCT 10MM IP68 CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 40V

Discontinued status rules out a fresh installation

No new design-in. One lifecycle signal calls E2E-X10F1 EOL; the lifecycle and product status fields say Discontinued. The labels differ, but the decision doesn't: this is a sustaining-design part, not a sensor to specify for a new machine. EU RoHS compliance does not alter its lifecycle status.

An M30 mounting point is only part of the fit

A controller input that cannot accept a 3-wire PNP-NO output rules this sensor out. In existing industrial machinery wired for that output, its M30 threaded cylinder and cable leads give a starting point for checking the installed mount and connection. The shielded inductive sensor has a listed 10 mm sensing distance, but that figure does not establish detection of the machine’s actual target.

The 400 Hz figure screens events, not response timing

400 Hz is the listed response frequency. It helps screen frequent target events, but it does not specify the switching delay needed to place an input transition in a controller sequence.

Bulk packaging complicates the sustaining buy

Bulk packaging is a poor match for a running line that expects a defined presentation. Cable leads help when they match the installed wiring, but they say nothing about handling at assembly. Secure inventory for existing production and plan migration; another order is not a new-design supply plan.

The listed 10 V to 40 V supply limits define the electrical window to check against the machine rail, not preferred setpoints at either endpoint. The stated -40°C to 85°C operating temperature range sets the environmental boundary; IP68 addresses ingress protection, not wiring or mounting fit. If the rail falls outside the supply limits or the installation falls outside the temperature range, a fitting M30 threaded body won't make the sensor usable there.

The 10 mm distance still needs target evidence

A 10 mm rating does not settle target detection. Sensing-distance-versus-target data are absent; so are the cable wiring diagram and mechanical drawing needed for connection and mounting checks.

View the Win-Source product page for E2E-X10F1.

Key Takeaways for Engineers & Buyers

  • Check the 10 mm sensing distance against the installed target.
  • Match the 3-wire PNP-NO output to the controller input.
  • For discontinued E2E-X10F1, secure inventory for existing production and plan migration.