Omron E2E-X10F2-M1: Discontinued, for sustaining only

E2E-X10F2-M1 Omron product image

10mm sensing distance, 10V to 40V supply limits, M30 threaded body and PNP-NC output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 40V

A 10mm sensing distance cannot rescue a discontinued sensor

10mm is the listed sensing distance for E2E-X10F2-M1, but it cannot justify a new design-in: both the lifecycle and product statuses say Discontinued. A separate lifecycle signal says EOL. The labels differ; the decision doesn’t. Keep the sensor to sustaining designs.

For an existing installation, measure target clearance against the 10mm figure. It does not prove every target will be detected at that distance. Listed EU RoHS compliance does not change the lifecycle verdict.

The 400Hz figure screens motion, not every missed target

A 400Hz response frequency cannot guarantee that every passing target will be caught. It does give a listed frequency against which to screen target passage rate before testing the mechanism. The supply limits are 10V and 40V: 40V is the ceiling, not a rail setpoint. A rail outside those bounds rules the sensor out; one inside them still leaves transient behavior unresolved.

The -40°C to 85°C operating-temperature range sets the stated envelope, with 85°C as its upper limit. It does not establish detection performance at either end.

M30 mounting makes this a sustaining-line purchase

The M30 thread and connector constrain physical fit. Bulk packaging is the listed supply format; arrange receiving and kitting for the existing line, secure units for production and plan migration rather than making this a new build standard.

The connector label leaves the installation questions open

That physical fit still leaves the cable question open. “Connector” gives neither a pinout nor a mating-connector specification, so it cannot establish whether the installed cable will connect correctly. Without a mechanical drawing, the M30 thread designation also cannot settle sensor-face position in the existing bracket.

The PNP-NC, 3-wire description identifies output behavior, but no output load-current rating is stated. The installed input or load remains unassessed. The target-material and mounting conditions behind the 10mm sensing distance are missing too. Before changing an installed sensor, those gaps matter: a matching thread and a plausible gap are not enough to establish that the machine will detect its target.

View the Win-Source product page for E2E-X10F2-M1.

Key Takeaways for Engineers & Buyers

  • Check the installed PNP-NC, 3-wire input before retaining E2E-X10F2-M1.
  • Measure target clearance against the listed 10mm sensing distance.
  • Secure units for existing production and plan migration from the discontinued part.