10mm sensing distance, 10V to 40V supply bounds, M30 body, -40°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCT 10MM IP68 CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 40V |
Discontinued status settles the new-design question
So that settles new design-in: E2E-X10F2 is discontinued, although one lifecycle entry says EOL and the status fields say Discontinued. It isn't for new designs; secure inventory for existing production and plan migration. EU RoHS compliance doesn't change that.
The 10mm reach sets placement before speed matters
Target placement is the first constraint: the 10mm sensing distance gives a published reach, but it does not establish that every target metal or size will switch at that gap. The 400Hz response frequency is a ceiling on detection rate, not the switching timing needed to judge a fast-moving target. The 10V to 40V supply bounds rule out rails beyond the listed range; 40V is a ceiling, not a working setpoint. Those limits suit a machine with controlled target geometry and a compatible supply, not one that depends on an untested sensing gap.
The M30 body belongs at a fixed machine position
Keep it on the machine. The shielded, threaded M30 cylinder and cable leads point to a fixed sensor mount; the PNP-NC, 3-wire output needs an input that accepts that polarity and contact state. IP68 is the listed ingress protection, but the cable termination still matters. The -40°C to 85°C operating temperature range sets the installation envelope; this listing gives no basis for qualification outside it.
Can the line handle bulk-packed cable-lead sensors?
Can receiving handle bulk-packed cable-lead sensors? Check the incoming process before committing E2E-X10F2 to an existing production build. The output load-current limit is absent, so the PNP-NC interface cannot be signed off from this listing. Get the datasheet’s target-material sensing correction before fixing the target gap, and its wiring diagram before releasing the field wiring. A mechanical drawing is absent too; the M30 designation alone cannot clear the bracket and cable exit.
View the Win-Source product page for E2E-X10F2.
Key Takeaways for Engineers & Buyers
- Keep E2E-X10F2 off new-design BOMs; plan migration for existing production.
- Check the machine rail against the 10V to 40V supply bounds.
- Match the PNP-NC, 3-wire output to the controller input.