Omron E2E-X10MB1DL18 2M: Active for new designs

E2E-X10MB1DL18 2M Omron product image

10mm sensing distance, 10V ~ 30V supply, M18 threaded body; PNP-NO cable-lead output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 10MM PNP M18 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V

The 10mm distance needs room around an unshielded M18 body

10mm is the listed sensing distance, not a guaranteed switch point for every target and mounting arrangement. This unshielded inductive sensor needs clearance around its M18 threaded body beside a metal target; don't assume it will fit an existing flush-mounted position. The PNP-NO, 3-Wire output is a firm choice too: moving the sensor won't make it work with a controller input arranged for a different output. Set the target position and input type before cutting the mounting plate.

Active status supports a new build, but cable leads need a plan

Cable leads leave termination to the assembly. Lifecycle and product status both say Active, with no conflict listed, so E2E-X10MB1DL18 2M is suitable for a new design-in when that termination fits the build. Put the cable connection on the assembly drawing before release. It is listed as EU RoHS compliant.

The supply window and response frequency bound the installation

Rail voltage is the first constraint. The listed supply range is 10V ~ 30V; 30V is a ceiling, not a target to exceed, and a rail outside the range rules this sensor out. The -40°C ~ 85°C operating-temperature window lets you screen the installation against its ambient conditions, but it says nothing about how sensing distance changes with temperature. The listed 400Hz response frequency can rule out a faster detection requirement. It does not describe the signal the controller will see at each transition.

IP67 and IP69K are listed ingress classifications, relevant when the sensor body faces water or washdown. Neither tells you how to route and protect the cable leads in the machine. The LED provides local indication; check the controller input during commissioning as well.

The M18 fit still needs a drawing

Not enough to release wiring. The listing has no cable connection diagram for the 3-Wire PNP-NO output or outline drawing for the M18 threaded body. It also lacks sensing-distance curves for different targets. Input wiring, mounting clearance, and switching margin remain open despite the listed 10mm sensing distance. Get those items before committing the sensor position or controller connection.

View the Win-Source product page for E2E-X10MB1DL18 2M.

Key Takeaways for Engineers & Buyers

  • Check target geometry against the listed 10mm sensing distance.
  • Keep the sensor supply within 10V ~ 30V.