10mm sensing, 10V ~ 30V supply limits, M18 body and -40°C ~ 85°C operating temperature
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM PNP M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
10mm reach decides whether this sensor gets a look
10mm is the listed sensing distance, not a promise that every target will switch at that separation. It is the first design-in check for E2E-X10MB1DL18-M1: if the target cannot pass within that reach, the Active lifecycle status does not rescue the choice. The 10V lower supply limit and 30V upper supply ceiling bound the power connection; neither establishes what the output can drive. The 400Hz response-frequency rating is a ceiling for event rate, not a switching-time specification. A faster-moving target needs a timing check.
The lifecycle signals agree on Active, so new design-in is reasonable if those checks pass. EU RoHS compliance is listed.
An unshielded M18 body needs room around the target
A tight metal mounting position is the wrong place to assume this sensor will achieve its listed reach. The inductive, unshielded M18 threaded body needs room for the target to approach the sensing face and for the installation to accommodate the sensor body. The -40°C to 85°C operating-temperature bounds set the environmental limits; a hotter location falls outside them. IP67 and IP69K are listed ingress ratings, but they do not settle exposure to every cleaning chemical. The PNP-NO, 3-wire output has to match the controller input. Termination is by connector, so the cable interface belongs in the build plan.
The connector is the purchasing constraint
That cable interface can stall the build: E2E-X10MB1DL18-M1 is connector-terminated, but the mating connector is not identified here. Identify it before releasing the assembly BOM. The sensor is listed in box packaging, not a stated assembly-feed format.
The missing drawing could change the mounting decision
The drawing isn't here. A dimensional drawing is needed to settle mounting clearance for the unshielded M18 body; the connector pinout is needed to wire the PNP-NO output correctly. The output-load current limit is also absent, so the listing cannot establish whether the sensor can drive the intended input. None of those details can be inferred from the sensing-distance rating.
View the Win-Source product page for E2E-X10MB1DL18-M1.
Key Takeaways for Engineers & Buyers
- Check the target position against the listed 10mm sensing distance.
- Match the controller input to the PNP-NO, 3-wire output.
- Identify the mating connector before releasing the assembly BOM.