10mm sensing limit, 10V–30V supply limits, threaded M12 body; PNP-NO cable output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 10MM PNP M12 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Can this active M12 sensor go into new production?
Can we put this sensor into a new production build? Yes. E2E-X10MB1TL12 2M is listed Active, with lifecycle signals in agreement; it supports new design-in when an inductive, PNP-NO sensor fits the machine. EU RoHS compliance is listed without a revision.
Before it reaches the production BOM, define how its cable leads connect on the machine, because the threaded M12 body does not turn the electrical connection into a plug-in one. The listed package is a box, not a connector choice. On existing lines, put the termination detail in the build instructions so assembly doesn't discover the wiring work after checking the mechanical fit.
The 10mm limit puts target position ahead of ingress ratings
10mm is the listed sensing-distance limit. It marks a placement boundary for a metal target, not a guaranteed trip point across targets and mounting arrangements. With an unshielded, threaded M12 body, surrounding metal and mounting geometry matter to the switching position.
The listed 400Hz response frequency is an event-rate screening ceiling, not a response-time specification. IP67 and IP69K are listed ingress ratings; they do not extend the sensing distance. The operating-temperature field spans -25°C to 70°C, so an installation outside that range is ruled out regardless of enclosure rating.
Does the 30V ceiling match the sensor rail?
30V is the listed supply ceiling; 10V is the lower bound. Those limits screen the sensor rail, not the load on the PNP-NO, 3-wire output. Without a listed output load-current limit, the listing cannot establish whether the output can drive the intended input.
Cable leads still need wiring and mounting details
Wiring isn't settled. E2E-X10MB1TL12 2M has cable leads, but no lead-identification diagram or pinout is given. Obtain that detail before assigning the PNP-NO output at the controller. A dimensional drawing is also absent, leaving the M12 mounting fit unresolved. The missing output load-current limit must come from the datasheet before the controller interface is settled.
View the Win-Source product page for E2E-X10MB1TL12 2M.
Key Takeaways for Engineers & Buyers
- Check the target position against the 10mm sensing-distance limit.
- Compare the event rate with the listed 400Hz response frequency.
- Keep the supply within the listed 10V–30V limits.