10mm sensing distance, 10V ~ 30V supply and M18 threaded body set the first fit checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 10MM PNP M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
The 10mm reach is a selection bound, not a target guarantee
10mm is the listed sensing distance. With little room to shift the target or sensor after assembly, that figure alone cannot establish where a particular target will switch this unshielded inductive sensor. The 10V ~ 30V supply range bounds rail selection, but its 30V ceiling doesn't settle what happens during a supply surge.
The 400Hz response-frequency ceiling limits event-rate selection; it is not a switching-delay figure. The -40°C ~ 85°C operating-temperature range covers the stated ambient conditions, but it leaves the effects of mounting and nearby heat unresolved for this installation. A marginal target position remains marginal despite those ratings.
Unshielded M18 mounting puts the machine geometry first
The unshielded M18 threaded body sets the mounting constraint. Its barrel format gives a defined mounting style, but surrounding metal and target position remain part of the fit decision. This is a PNP-NO, 3-wire inductive sensor: the input must accept that output arrangement, because adjusting the mount won't change its switching behavior. IP67 and IP69K are listed ingress ratings, not a reason to overlook how the installed cable enters the machine.
Active status supports a new E2E-X10MB1TL18 2M design-in
New design-in is reasonable. All lifecycle signals say Active, with no conflict to resolve, and EU RoHS compliance is listed. Keep the purchasing distinction clear: Box describes packaging, while Cable Leads describes termination. Put the cable-lead termination on the assembly drawing so a boxed sensor is not mistaken for a connectorized one.
Cable leads rule out a plug-in sensor position
A plug-in sensor position is wrong for cable leads. Use it where machine wiring can accept a routed cable and the M18 body can face the target. The LED provides local indication at that installed position.
The pinout and mounting drawing still have to settle fit
That still leaves the connection and fit unresolved: the listing has no pinout, mounting drawing or target-dependent sensing-distance data. Those items are needed to assign the 3-wire connection, check physical clearance and determine whether the actual target can be detected at the intended position.
View the Win-Source product page for E2E-X10MB1TL18 2M.
Key Takeaways for Engineers & Buyers
- Check the actual target against the listed 10mm sensing distance.
- Keep the required event rate within the listed 400Hz response-frequency ceiling.
- Check the machine rail against the 10V ~ 30V supply range.